Model: ECO-PIR-WL This is a professional-grade Passive Infrared (PIR) motion sensor engineered for energy-efficient automation within smart hotel environments.
The ECO-PIR-WL is a professional-grade Passive Infrared (PIR) motion sensor engineered for energy-efficient automation within smart hotel environments. Utilizing enhanced quad-element PIR sensing technology, the device delivers precise motion detection and signal capture. As a core trigger component of the hotel's "3+1" energy-saving framework, it leverages LoRa technology for robust, long-range wireless communication, providing guestroom power management systems with reliable occupancy data. This facilitates high-efficiency energy control while ensuring total guest privacy.
Features
Equipped with PIR motion detection.
Quad-element PIR technology enhances radial movement detection and minimizes blind spots.
Utilizes license-free ISM LoRa bands (470–928MHz) to ensure robust, long-range wireless connectivity and superior wall penetration in dense hotel infrastructures.
Enables remote monitoring and adjustment of sensor parameters (sensitivity, range, delays) via the gateway interface.
Supports parameter configuration and status readout via IR remote control.
Specifications
Communication Type
Wireless (LoRa Technology)
Cloud Ecosystem
Tuya-WiFi (Supports remote parameter configuration via Gateway)
BOX Input Voltage
AC 100 to 240 V
BOX Output Voltage
DC 12 V (< 500 mA)
Sensor Input Voltage
DC 12 V
Power Consumption
0.5 W (Max)
Indicator Light
LED
Detection Mode
Pyroelectric Infrared Receiver
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
When the installation height is 3.0 m, the motion detection diameter is ≤ 6.0 m
Delay Time
1 to 3,600 seconds
Product Size
Φ43 mm x 25 mm
Cutout Size
Φ35 mm
Product Weight
14.5 g
BOX Size
84 mm x 26 mm x 21 mm
BOX Weight
30 g
Cable Assembly
UL2468 22AWG Cable Length: 200 mm
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Front View
Top View
Dimensions
Measuring 43 mm wide and 25 mm deep, this recessed unit fits a 35 mm cutout and requires a minimum ceiling depth of 10 cm.
Product Dimensions
Applications
Hotel
Mounting
Interference Avoidance: Avoid installing near moving objects (e.g., pets, swinging curtains) or areas with rapid temperature changes (e.g., AC vents, heat sources) to ensure accuracy and prevent false alarms.
Device Spacing: Maintain at least 4m between sensors.
Mounting: Install on a stable, vibration-free surface. Ensure no moving objects are behind the wall (signals penetrate non-metals).
Wiring Safety: Disconnect power before wiring. Use certified cables and strictly follow the diagram to ensure proper circuit protection.
Disclaimer: Follow wiring diagrams strictly. Manufacturer is not liable for improper installation. Specifications subject to change.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
Where is the Tuya communication module for this wireless PIR model?
The Tuya WiFi module is directly built inside the sensor probe body. Not only does it support LoRa long-distance communication and gateway linkage, but its built-in Tuya WiFi also allows direct remote monitoring and configuration adjustment via the gateway interface.
How is the power supply for the sensor resolved?
Adopts a separated design. The probe is powered by a matching ultra-small power supply box (BOX). The BOX connects to AC 100-240V mains and outputs stable DC 12V low voltage for the probe to operate (probe max power consumption is only 0.5W).
Why does the ECO system choose LoRa technology instead of ordinary wireless?
Hotel guest rooms have many partition walls and doors, making ordinary wireless highly prone to dropping. LoRa uses globally unlicensed ISM bands (470-928 MHz), possessing excellent wall-penetrating capabilities and long-distance stability, ensuring sensor signals stably penetrate walls to reach the guest room's master control gateway.
What is the advantage of quad PIR technology in guest rooms compared to ordinary infrared?
Ordinary dual-element infrared is sensitive to human transverse walking but highly insensitive to radial (walking head-on) movement, easily creating blind spots. Quad PIR technology greatly enhances radial motion capture capability, achieving 6-meter diameter blind-spot-free omnidirectional coverage at a 3-meter height, preventing lights from turning off while guests are walking.
Are there rigid requirements for the sensor's installation height?
The recommended installation height is 2.0 to 3.2 meters. If the ceiling is too high, it may exceed the effective focusing range of the PIR Fresnel lens, leading to a severe drop in sensitivity.
What are the body dimensions and cutout requirements?
The sensor body diameter is 43mm and the thickness is only 25mm. Only a 35mm circular hole needs to be cut in the ceiling for recessed hidden installation, which is extremely aesthetic.
Will it cause false alarms if the installation position faces the glass door of the guest room restroom?
No. Infrared (PIR) cannot penetrate ordinary glass, so it will not sense personnel activity on the other side of the glass door. However, care must be taken to avoid AC vents; hot and cold airflows will severely interfere with PIR causing false triggers.
How to adjust parameters when disconnected from the network?
Fully supports localized operations. Electricians can use the RC1 remote aimed directly at the body's sensing surface to issue 1-3600 seconds delay and sensitivity commands, and the parameters are instantly written into effect.