This is a high-precision dual-tech presence sensor designed for the Tuya Smart ecosystem.
$9,999.00 $9,999.00
Received successfully
Coupon Code
CONTINUE SHOPPING
    Please select the information you wantX
Quantity:
-
+
  • R7 Dual-Tech Presence Sensor (Tuya WiFi & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya WiFi & Switch 300W)
  • R7 Dual-Tech Presence Sensor (Tuya WiFi & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya WiFi & Switch 300W)
1/1
  • R7 Dual-Tech Presence Sensor (Tuya WiFi & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya WiFi & Switch 300W)
  • Description
  • Resources

Overview

The CTL-SEN-R7/3720 is a high-precision dual-tech presence sensor designed for the Tuya Smart ecosystem. Combining 24GHz FMCW mmWave radar with PIR technology, its cross-validation and self-learning capabilities detect subtle micro-motions (like breathing) while eliminating false alarms from airflows and thermal changes. With TY-WiFi support, wide-range AC 100–240V power, and a built-in 0–32,000 Lux daylight sensor, it provides a stable, low-latency sensing solution for smart building automation.

Features

  • Supports standard Tuya WiFi protocol for fast networking, stable connection, and seamless Tuya ecosystem integration.
  • 24GHz FMCW radar and PIR cross-verification minimizes false alarms.
  • Captures subtle breathing; accurately detects major motion, micro-motion, and stationary presence.
  • Built-in 0–32,000 Lux light sensor enables intelligent automated dimming.
  • Built-in relay directly drives lights without external relays.
  • Sensitivity and detection range can be adjusted independently.
  • Allows easy parameter configuration and status readback via remote.
  • Indicator brightness automatically adjusts to ambient lighting.

Specifications

Communication Type TY-WiFi
Input Voltage AC 100 to 240 V
Power Consumption 0.5 W (Max)
Relay Output Normally Open Mode, Normally Closed Mode
Relay Load AC 100 to 240 V, ≤ 2 A
Indicator Light LED
Detection Mode 24GHz FMCW Radar + PIR
Operating Frequency 24.00 to 24.25 GHz
Transmit Power ≤ 10 dBm
Installation Method Recessed Ceiling Mount
Mounting Height 2.0 to 3.2 m
Detection Angle 360°
Detection Coverage Installation at 3.0 m Height:
① Motion & Micro-motion: Detection diameter at least 8.0m
② Stationary Presence: Detection diameter at least 6.0m
Detection Range 1.5 to 8.0 m (sensor to target)
Sensitivity Highest, High, Medium, Low, Lowest
Illuminance Monitoring 0 to 32,000 Lux (Accuracy ±4%)
Delay Time 5 to 3,600 seconds
Product Size Φ60 mm x 65 mm
Cutout Size Φ50 mm
Product Weight 65 g
Operating Temperature Indoor -20 to 45°C
Operating Humidity < 95% RH (Non-condensing)
Storage Temperature -40 to 85°C
Protection Level IP20
Housing Material PC

Range

Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this dual-tech presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.

R7-DTP-TYW/S1 detection range, Front View
Front View
R7-DTP-TYW/S1 detection range, Side View
Side View

Dimensions

The flush-mounted sensor has an outer diameter of 60 mm, a depth of 65 mm, and fits standard Φ50 mm ceiling cutouts.

Product Dimensions
Product Dimensions

Applications

R7-DTP-TYW/S1 application: Home
Home
R7-DTP-TYW/S1 application: Hotel
Hotel
R7-DTP-TYW/S1 application: Lighting
Lighting
R7-DTP-TYW/S1 application: Office
Office
R7-DTP-TYW/S1 application: Security
Security

Mounting

Interference Mitigation: Keep away from moving objects (curtains, fans, plants), reflective metal/glass surfaces, HVAC air vents, and EMI sources. Adjust detection range to prevent false triggers through thin partitions.

Device Spacing: Maintain at least 4 meters between sensors; avoid pointing radar faces directly at each other to prevent co-channel interference.

Mounting & Handling: Mount on a solid, vibration-free surface and avoid flimsy, vibrating panels. Handle with care without pressing on the Fresnel lens or internal antenna.

Electrical Safety: Powered by AC 100–240V. Turn off mains power before wiring; must be installed by a qualified electrician. Use flame-retardant wiring without exposed cores, and ensure upstream circuits include leakage and overload protection.

Packaging Disposal: Recycle packaging per local environmental regulations. Keep plastic bags away from children to avoid suffocation hazards.

Disclaimer: Specifications are subject to change without notice. The manufacturer is not liable for device damage or losses caused by improper wiring, mounting, or uncalibrated conditions.

R7-DTP-TYW/S1 wiring diagram
Wiring Diagram

Debugging

IR Remote Control
IR Remote Control

Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.

Tuya Smart
Tuya Smart
Tuya Smart
Tuya Smart

Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.

FAQ

How does this model (TYW/S1) differ from a regular sensing node in lighting control?

It is a true all-in-one "sensing controller". Not only does it have a built-in Tuya WiFi module connecting directly to an external router, but the body also integrates a control relay internally (supporting max 2A approx. 300W load). Based on human presence, it can directly cut off or conduct the high-voltage live wire of the connected luminaires, achieving local hard-controlled lighting without relying on a gateway.

If the external WiFi drops offline, can it still automatically turn off lights when people leave?

Yes. The detection judgment of radar and PIR, as well as the trigger logic for the internal relay, are executed in a closed loop within the local chip in the body. External network interruption only affects the App's remote monitoring; the local automated sensing light control is not affected in the slightest.

What directionality should be noted when installed in a narrow corridor?

Although radar waves are omnidirectional, the PIR lens at the bottom of the body contains specific optical arrays. The sensing surface is printed with a clear "triangle orientation marker". During installation, its arrow direction should be aligned with the corridor's extension direction to achieve the best cutting sensing effect.

What are the consequences of installing multiple R7 sensors too close?

It easily causes co-channel cross-talk of FMCW millimeter waves. Microwave emissions are easily picked up by nearby receivers, raising the noise floor and causing false alarms. When deploying multiple devices on-site, a straight-line spacing of at least 4 meters must be maintained, and avoid aiming the sensing surfaces directly at each other.

Are the wiring terminals safe?

The safety design standard is relatively high. The high-voltage wiring terminals are integrated on the top of the body. During construction, please use standard hard copper wires or soft wires with ferrules to ensure no copper core is exposed. Additionally, be sure to equip leakage and overload protectors in the front-end distribution box.

What are the body dimensions and installation depth requirements?

The body outer diameter is 60 mm, and the ceiling cutout requires 50 mm. Because the whole machine contains the power supply and relay, the depth reaches 65 mm. Plus the top wiring space, sufficient hiding depth must be left inside the ceiling.

How long a delay time can be set in the Tuya APP?

Supports wide-range adjustment; the light-off delay time can be freely set between 5 seconds and 3600 seconds (1 hour), meeting different needs from short stays in corridors to long stays in conference rooms.

What should be noted during daily cleaning?