$0.00 $0.00
Please choose options.Back to top
Close
$0.00 $0.00
Home > All Products > R7 Series > R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W)
  • R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W)
1/1
  • R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W)

R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W)

No.R7-DTP-TYZ/S1
P/N: 60.70.3710
Model: CTL-SEN-R7/3710
This is a high-precision dual-tech presence sensor designed for the Tuya Smart ecosystem.
$9,999.00 $9,999.00
Received successfully
Coupon Code
CONTINUE SHOPPING
    Please select the information you wantX
Quantity:
-
+
  • R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W)
  • R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W)
1/1
  • R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Tuya Zigbee & Switch 300W)
  • Description
  • Resources

Overview

The CTL-SEN-R7/3710 is a high-precision dual-tech presence sensor designed for the Tuya Smart ecosystem. Combining 24GHz FMCW mmWave radar with PIR technology, its cross-validation and self-learning capabilities detect subtle micro-motions (like breathing) while eliminating false alarms from airflows and thermal changes. With TY-Zigbee support, wide-range AC 100–240V power, and a built-in 0–32,000 Lux daylight sensor, it provides a stable, low-latency sensing solution for smart building automation.

Features

  • Supports standard Tuya Zigbee protocol for fast networking, stable connection, and seamless Tuya ecosystem integration.
  • 24GHz FMCW radar and PIR cross-verification minimizes false alarms.
  • Captures subtle breathing; accurately detects major motion, micro-motion, and stationary presence.
  • Built-in 0–32,000 Lux light sensor enables intelligent automated dimming.
  • Built-in relay directly drives lights without external relays.
  • Sensitivity and detection range can be adjusted independently.
  • Allows easy parameter configuration and status readback via remote.
  • Indicator brightness automatically adjusts to ambient lighting.

Specifications

Communication Type TY-ZigBee
Input Voltage AC 100 to 240 V
Power Consumption 0.5 W (Max)
Relay Output Normally Open Mode, Normally Closed Mode
Relay Load AC 100 to 240 V, ≤ 2 A
Indicator Light LED
Detection Mode 24GHz FMCW Radar + PIR
Operating Frequency 24.00 to 24.25 GHz
Transmit Power ≤ 10 dBm
Installation Method Recessed Ceiling Mount
Mounting Height 2.0 to 3.2 m
Detection Angle 360°
Detection Coverage Installation at 3.0 m Height:
① Motion & Micro-motion: Detection diameter at least 8.0m
② Stationary Presence: Detection diameter at least 6.0m
Detection Range 1.5 to 8.0 m (sensor to target)
Sensitivity Highest, High, Medium, Low, Lowest
Illuminance Monitoring 0 to 32,000 Lux (Accuracy ±4%)
Delay Time 5 to 3,600 seconds
Product Size Φ60 mm x 65 mm
Cutout Size Φ50 mm
Product Weight 65 g
Operating Temperature Indoor -20 to 45°C
Operating Humidity < 95% RH (Non-condensing)
Storage Temperature -40 to 85°C
Protection Level IP20
Housing Material PC

Range

Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this dual-tech presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.

R7-DTP-TYZ/S1 detection range, Front View
Front View
R7-DTP-TYZ/S1 detection range, Side View
Side View

Dimensions

The flush-mounted sensor has an outer diameter of 60 mm, a depth of 65 mm, and fits standard Φ50 mm ceiling cutouts.

Product Dimensions
Product Dimensions

Applications

R7-DTP-TYZ/S1 application: Home
Home
R7-DTP-TYZ/S1 application: Hotel
Hotel
R7-DTP-TYZ/S1 application: Lighting
Lighting
R7-DTP-TYZ/S1 application: Office
Office
R7-DTP-TYZ/S1 application: Security
Security

Mounting

Interference Mitigation: Keep away from moving objects (curtains, fans, plants), reflective metal/glass surfaces, HVAC air vents, and EMI sources. Adjust detection range to prevent false triggers through thin partitions.

Device Spacing: Maintain at least 4 meters between sensors; avoid pointing radar faces directly at each other to prevent co-channel interference.

Mounting & Handling: Mount on a solid, vibration-free surface and avoid flimsy, vibrating panels. Handle with care without pressing on the Fresnel lens or internal antenna.

Electrical Safety: Powered by AC 100–240V. Turn off mains power before wiring; must be installed by a qualified electrician. Use flame-retardant wiring without exposed cores, and ensure upstream circuits include leakage and overload protection.

Packaging Disposal: Recycle packaging per local environmental regulations. Keep plastic bags away from children to avoid suffocation hazards.

Disclaimer: Specifications are subject to change without notice. The manufacturer is not liable for device damage or losses caused by improper wiring, mounting, or uncalibrated conditions.

R7-DTP-TYZ/S1 wiring diagram
Wiring Diagram

Debugging

IR Remote Control
IR Remote Control

Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.

Tuya Smart
Tuya Smart
Tuya Smart
Tuya Smart

Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.

FAQ

What is the difference in system architecture between this model and the Tuya WiFi version?

This model has a built-in Tuya ZigBee communication module. Compared to WiFi relying on a single router, ZigBee uses low-power local ad-hoc networking technology. When densely deployed in large hotels or office areas, it doesn't consume main router IPs, and even if the external network is disconnected, the local ZigBee gateway can still maintain basic linkages.

Does this device come with its own high-voltage relay to control luminaires?

Yes. It is a high-voltage controlled dual-tech sensor. The body not only has a ZigBee module but also integrates a 2A (approx. 300W load) control relay, directly opening or closing the connected mains luminaire circuit based on personnel presence status.

What troubleshooting advantage does dual-technology have applied in environments like restrooms?

Restrooms often have exhaust fan vibrations and water vapor temperature changes, very easily causing false triggers in a single radar or single PIR. Because the cross-validation mechanism compulsorily requires both to detect biological characteristics before judging occupancy, it effectively filters out false alarms caused by fan vibrations (which have no infrared heat source).

How to prevent mutual interference when multiple R7 radars are close to each other?

Microwave signals are prone to co-channel cross-talk. If installed on the same large floor, two devices must maintain a straight-line physical spacing of at least 4 meters; meanwhile, please avoid aiming the sensing surfaces of two radars directly at each other across space.

Can parameters be changed via remote control when not connected to the network?

Absolutely. The site supports using the RC1 remote aimed at the body to contactlessly override the underlying sensitivity, light-sensitive threshold, and delay time (5~3600s) of the chip. This provides electricians with extremely convenient netless offline debugging means.

What are the requirements for the body cutout size and concealed installation depth?

The ceiling cutout diameter requires 50 mm. Because a transformer and relay are integrated internally, the body depth is relatively deep (65mm); plus the top high-voltage cables need bending, it is recommended that the vertical clearance depth inside the ceiling be no less than 80mm.

Will it cause false alarms if the installation position directly faces a glass partition?

There is a certain probability. Although glass blocks PIR thermal radiation, reducing the dual-tech trigger probability, the 24GHz FMCW radar waves can pass through glass to perceive outdoor movement. It is recommended to use sensitivity adjustment to shrink the detection distance within the glass range, or change the installation position.

Is ambient illuminance monitoring integrated to assist dimming?

Yes, the body has a built-in high-precision ambient light sensor (0-32,000 Lux). Light intensity data can be reported via ZigBee, and the system, combined with timeline scene logic, can achieve a dim and soft transition of lighting during nighttime personnel activity.

Resources

Available Accessories

Remote Controller
Remote Controller P/N: 60.99.00C1

Model: Accessory (RC1)

Related Links

Frequently Bought Together
more
Frequently Bought Together

Download

Message Us