The CTL-SEN-R7/3620 is a high-precision dual-tech presence sensor designed for the Tuya Smart ecosystem. Combining 24GHz FMCW mmWave radar with PIR technology, its cross-validation and self-learning capabilities detect subtle micro-motions (like breathing) while eliminating false alarms from airflows and thermal changes. With TY-WiFi support, wide-range AC 100–240V power, and a built-in 0–32,000 Lux daylight sensor, it provides a stable, low-latency sensing solution for smart building automation.
Features
Supports standard Tuya WiFi protocol for fast networking, stable connection, and seamless Tuya ecosystem integration.
24GHz FMCW radar and PIR cross-verification minimizes false alarms.
Captures subtle breathing; accurately detects major motion, micro-motion, and stationary presence.
Adapts intelligently to complex spaces for quick, simple commissioning.
Sensitivity and detection range can be adjusted independently.
Allows easy parameter configuration and status readback via remote.
Indicator brightness automatically adjusts to ambient lighting.
Specifications
Communication Type
TY-WiFi
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Indicator Light
LED
Detection Mode
24GHz FMCW Radar + PIR
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 3.2 m
Detection Angle
360°
Detection Coverage
Installation at 3.0 m Height: ① Motion & Micro-motion: Detection diameter at least 8.0m ② Stationary Presence: Detection diameter at least 6.0m
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
Highest, High, Medium, Low, Lowest
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
5 to 3,600 seconds
Product Size
Φ60 mm x 65 mm
Cutout Size
Φ50 mm
Product Weight
65 g
Operating Temperature
Indoor -20 to 45°C
Operating Humidity
< 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this dual-tech presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.
Front View
Side View
Dimensions
The flush-mounted sensor has an outer diameter of 60 mm, a depth of 65 mm, and fits standard Φ50 mm ceiling cutouts.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Mitigation: Keep away from moving objects (curtains, fans, plants), reflective metal/glass surfaces, HVAC air vents, and EMI sources. Adjust detection range to prevent false triggers through thin partitions.
Device Spacing: Maintain at least 4 meters between sensors; avoid pointing radar faces directly at each other to prevent co-channel interference.
Mounting & Handling: Mount on a solid, vibration-free surface and avoid flimsy, vibrating panels. Handle with care without pressing on the Fresnel lens or internal antenna.
Electrical Safety: Powered by AC 100–240V. Turn off mains power before wiring; must be installed by a qualified electrician. Use flame-retardant wiring without exposed cores, and ensure upstream circuits include leakage and overload protection.
Packaging Disposal: Recycle packaging per local environmental regulations. Keep plastic bags away from children to avoid suffocation hazards.
Disclaimer: Specifications are subject to change without notice. The manufacturer is not liable for device damage or losses caused by improper wiring, mounting, or uncalibrated conditions.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
This R7-TYW model has no relay. What is its main role in the system?
It is a pure data collection node for personnel status and lighting with advanced "dual-tech detection" capabilities. Relying on the Tuya WiFi module built into the all-in-one body, it reports precise presence information and illuminance values to the Tuya cloud, and cloud automation scenes trigger the control of luminaire switches under the same network. Not having a relay drives the hardware cost further down.
What are the on-site wiring requirements for the power supply terminals? Need an external transformer?
Absolutely no external transformer is needed. The top of this all-in-one body directly provides AC 100~240 V mains input wiring ports. Electricians just need to connect the L (live wire) and N (neutral wire) after powering off to boot and run, which is very convenient.
How does the FMCW radar used in dual-technology help compared to traditional technologies?
Traditional infrared (PIR) very easily loses targets when personnel sit still reading or working due to no major movements. FMCW (Frequency-Modulated Continuous-Wave) radar can detect tiny undulations like chest breathing through distance changes. Cross-validation combines the radar's high sensitivity with PIR's anti-clutter characteristics, enabling accurate occupancy judgment even when personnel sit still in a 6.0-meter area.
If there is intense direct sunlight on-site, will it cause severe false alarms?
Mostly avoided. The severe local temperature difference caused by sunlight does interfere with PIR causing fluctuations, but the dual-tech logic requires the FMCW radar to also detect solid physical micro-motion before acting. Sunlight cannot trigger radar micro-motion, thereby blocking such environmental false alarms.
What is the function of the button on the body surface?
Since this version has no relay, its button is exclusively for network configuration. Long-pressing this "Pairing Button" resets the built-in WiFi, putting the device into pairing status, convenient for electricians to quickly rebind after initial installation or router password changes.
What are the body dimensions and concealed installation depth requirements?
The body outer diameter is 60 mm, requiring a ceiling cutout diameter of 50 mm. Because the whole machine contains a power board, its depth is 65 mm. To guarantee the safety of top wiring and not break the wire cores, it is recommended to retain at least 80 mm of vertical clearance in the ceiling cavity.
Will installing in metal gussets affect the signal?
It will cause severe failure. Metal plates completely reflect and shield FMCW radar microwaves. The sensing surface at the bottom of the sensor must be completely exposed outside the metal ceiling; it is strictly prohibited for metal structures to surround or block its emission cone cross-section.
If there is no network on-site, can the sensing distance and delay be adjusted independently?
Yes. In addition to network-issued parameter tuning, the site fully supports using the matching RC1 remote aimed at the sensing surface to contactlessly and instantly override the device's underlying sensitivity gears and delay modification commands (5~3600s).