$0.00 $0.00
Please choose options.Back to top
Close
$0.00 $0.00
Home > All Products > R7 Series > R7 Dual-Tech Presence Sensor (Switch 300W)
  • R7 Dual-Tech Presence Sensor (Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Switch 300W)
1/1
  • R7 Dual-Tech Presence Sensor (Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Switch 300W)

R7 Dual-Tech Presence Sensor (Switch 300W)

No.R7-DTP-S1
P/N: 60.70.3100
Model: CTL-SEN-R7/3100
This is a high-precision dual-tech presence sensor designed for smart buildings and space automation.
$9,999.00 $9,999.00
Received successfully
Coupon Code
CONTINUE SHOPPING
    Please select the information you wantX
Quantity:
-
+
  • R7 Dual-Tech Presence Sensor (Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Switch 300W)
  • R7 Dual-Tech Presence Sensor (Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Switch 300W)
1/1
  • R7 Dual-Tech Presence Sensor (Switch 300W),CREATROL SENSOR,R7 Dual-Tech Presence Sensor (Switch 300W)
  • Description
  • Resources

Overview

The CTL-SEN-R7/3100 is a high-precision dual-tech presence sensor designed for smart buildings and space automation. Combining 24GHz FMCW radar with PIR technology, its cross-validation and self-learning algorithms detect subtle micro-motions (like breathing) while eliminating false alarms from airflows and temperature drift. With direct AC 100–240V power, an onboard relay output, and a 0–32,000 Lux daylight sensor, it provides an all-in-one sensing and control solution.

Features

  • 24GHz FMCW radar and PIR cross-validation minimizes false triggers.
  • Captures subtle breathing; distinguishes between major motion, micro-motion, and stationary presence.
  • Built-in precision light sensor enables automated intelligent dimming.
  • Adapts automatically to complex environments for fast commissioning.
  • Sensitivity and detection range can be adjusted independently.
  • Built-in relay directly drives lights without external relays.
  • Allows easy parameter setting and status readback via remote.
  • Indicator brightness adjusts automatically to ambient light.
  • Powered by an in-house core module with advanced signal processing.

Specifications

Output Type Mains Output
Input Voltage AC 100 to 240 V
Power Consumption 0.5 W (Max)
Relay Output Normally Open Mode, Normally Closed Mode
Relay Load AC 100 to 240 V, ≤ 2 A
Indicator Light LED
Detection Mode 24GHz FMCW Radar + PIR
Operating Frequency 24.00 to 24.25 GHz
Transmit Power ≤ 10 dBm
Installation Method Recessed Ceiling Mount
Mounting Height 2.0 to 3.2 m
Detection Angle 360°
Detection Coverage Installation at 3.0 m Height:
① Motion & Micro-motion: Detection diameter at least 8.0m
② Stationary Presence: Detection diameter at least 6.0m
Detection Range 1.5 to 8.0 m (sensor to target)
Sensitivity Highest, High, Medium, Low, Lowest
Illuminance Monitoring 0 to 32,000 Lux (Accuracy ±4%)
Delay Time 5 to 3,600 seconds
Product Size Φ60 mm x 65 mm
Cutout Size Φ50 mm
Product Weight 65 g
Operating Temperature Indoor -20 to 45°C
Operating Humidity < 95% RH (Non-condensing)
Storage Temperature -40 to 85°C
Protection Level IP20
Housing Material PC

Range

Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this dual-tech presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.

R7-DTP-S1 detection range, Front View
Front View
R7-DTP-S1 detection range, Side View
Side View

Dimensions

The flush-mounted sensor has an outer diameter of 60 mm, a depth of 65 mm, and fits standard Φ50 mm ceiling cutouts.

Product Dimensions
Product Dimensions

Applications

R7-DTP-S1 application: Home
Home
R7-DTP-S1 application: Hotel
Hotel
R7-DTP-S1 application: Lighting
Lighting
R7-DTP-S1 application: Office
Office
R7-DTP-S1 application: Security
Security

Mounting

Interference Mitigation: Keep away from moving objects (curtains, fans, plants), reflective metal/glass surfaces, HVAC air vents, and EMI sources. Adjust detection range to prevent false triggers through thin partitions.

Device Spacing: Maintain at least 4 meters between sensors; avoid pointing radar faces directly at each other to prevent co-channel interference.

Mounting & Handling: Mount on a solid, vibration-free surface and avoid flimsy, vibrating panels. Handle with care without pressing on the Fresnel lens or internal antenna.

Electrical Safety: Powered by AC 100–240V. Turn off mains power before wiring; must be installed by a qualified electrician. Use flame-retardant wiring without exposed cores, and ensure upstream circuits include leakage and overload protection.

Packaging Disposal: Recycle packaging per local environmental regulations. Keep plastic bags away from children to avoid suffocation hazards.

Disclaimer: Specifications are subject to change without notice. The manufacturer is not liable for device damage or losses caused by improper wiring, mounting, or uncalibrated conditions.

R7-DTP-S1 wiring diagram
Wiring Diagram

Debugging

IR Remote Control
IR Remote Control

Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.

FAQ

Does this model support mobile APP or Tuya network control?

No. This is a pure local hardwired control model. The body internally does not contain any Tuya or other wireless communication modules. It relies on low-level dual-tech radar algorithms to directly hard-control the on/off of the internal relay, with extremely fast response and no network required.

How are the power supply and load-carrying capacities for installing this device?

Power supply is extremely simple; the top of the body provides wiring terminals to connect directly to AC 100 ~ 240 V mains. Internally integrating a 1-channel relay, it can carry a maximum current of 2A, suitable for independently controlling the main lighting circuit of a single office or entryway area of about 300W.

How does the FMCW radar used in dual-technology help compared to traditional technologies?

Traditional PIR sensors easily lose targets when personnel sit still. FMCW (Frequency-Modulated Continuous-Wave) radar can identify tiny undulations like breathing through distance changes. As long as a person is within the 6-meter diameter static detection area, the radar can stably capture them, accurately judge presence, and prevent lights from turning off mistakenly.

If there is intense direct sunlight on-site, will it cause severe false alarms?

Mostly avoided. The temperature difference of sunlight interferes with PIR, but because dual-tech requires the FMCW radar to also detect movement before outputting an action, sunlight is hard to trigger radar micro-motion, thereby suppressing this kind of environmental interference false alarm.

How to issue illuminance and delay parameters for a pure local model?

Configuration is very efficient. On-site engineering personnel can use the standard RC1 remote aimed directly at the body sensing surface to send commands. The light-off delay time supports a wide range setting between 5 seconds and 3600 seconds.

What is the use of the "Test Button" on the body surface?

This is mainly provided for on-site electricians for troubleshooting. Short-pressing this test button can bypass the detection logic to manually force close or open the internal 220V relay. This way, electricians can immediately know if the high-voltage wiring on the ceiling is conductive and if the bulb is burnt out.

What size hole saw needs to be used during installation?

The cutout requirement for R7 is 50 mm. Because it integrates a transformer and relay internally, the body depth is relatively deep (65mm); please ensure there is sufficient vertical clearance inside the ceiling during installation.

Is it possible to externally connect a manual switch on-site to control the luminaires?

This compact R7 model currently only provides L and N power input terminals and L1 output terminals on the top, with no dedicated manual override switch wiring port set. Daily use relies entirely on the sensor's high-precision automatic control.

Resources

Available Accessories

Remote Controller
Remote Controller P/N: 60.99.00C1

Model: Accessory (RC1)

Related Links

Frequently Bought Together
more
Frequently Bought Together

Download

Message Us