$0.00 $0.00
Please choose options.Back to top
Close
$0.00 $0.00
Home > All Products > R5 Series > R5_RS485 > 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
1/1
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)

60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)

No.R5-60G-485
P/N: 60.50.6208
Model: CTL-SEN-R5/6208
This is a flagship human presence sensor powered by advanced 60GHz 4D mmWave radar technology.
$439.80 $108.40
Received successfully
Coupon Code
CONTINUE SHOPPING
    Please select the information you wantX
Quantity:
-
+
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
1/1
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • 60G Eldercare Radar Sensor Fall/Get Up/Presence (RS485)
  • Description
  • Resources

Overview

The CTL-SEN-R5/6208 is a flagship human presence sensor powered by advanced 60GHz 4D mmWave radar technology. Featuring a robust 4T4R antenna array, it delivers ultra-high resolution to support complex functions, including real-time trajectory tracking, people counting, fall detection, and precise bed occupancy monitoring (in-bed/out-of-bed status). By capturing minute physiological signals (such as breathing), it ensures reliable performance within a Φ6.0-meter coverage area, making it an ideal solution for premium smart home, healthcare, and elderly care applications.

Features

  • Presence: Detects stationary presence via breathing micro-motions within 5.0 x 6.0m.
  • Fall Detection: Real-time fall identification via point cloud and posture analysis.
  • Bed Monitor: Tracks "in-bed" vs. "out-of-bed" status in defined zones.
  • Zone Alert: Monitors boundaries (e.g., doorways) for entry/exit alerts.
  • Counting: Real-time counting and location tracking for space management.
  • Sensitivity and detection distance can be adjusted independently.
  • Integrated high-precision sensor for accurate indoor illuminance monitoring.
  • Supports multiple protocols via RS485, including Modbus-RTU and Active Reporting.
  • Adjustable lighting threshold.
  • Supports parameter configuration and status readout via IR remote control.
  • Indicator LED brightness automatically adjusts to ambient light levels.

Specifications

Communication Type RS485 + Dry Contact
Input Voltage DC 12 to 30 V
Power Consumption ≤ 3 W
Serial Port Settings Baud Rate: 1200 to 115200
Data Bits: 8
Parity: None, Even, Odd
Stop Bits: 1 to 2
Default: 9600, 8, None, 1
Address Range 01 to 99 (Decimal)
Dry Contact Output Normally Open Mode, Normally Closed Mode, Normally Open Pulse, Normally Closed Pulse
(Defaults to Fall function)
Dry Contact Load AC or DC ≤ 30 V, ≤ 200mA
Indicator Light RGB LED
Detection Mode 60GHz FMCW Radar
Antenna Array 4T4R
Operating Frequency 60 to 64 GHz
Transmit Power ≤ 10 dBm
Installation Method Recessed Ceiling Mount
Mounting Height 2.0 to 3.2 m
Detection Angle 360°
Detection Coverage 5.0 x 6.0 m
Detection Range 1.0 to 6.0 m (sensor to target)
Sensitivity 0% to 100%
Illuminance Monitoring 0 to 32,000 Lux (Accuracy ±4%)
Delay Time 1 to 3,600 seconds
Product Size Φ65 mm x 60 mm
Cutout Size Φ55 mm
Product Weight 70 g
Cable Assembly UL1007 20AWG
Cable Length: 150 mm
Operating Temperature Indoor -20 to 45°C
Operating Humidity < 95% RH (Non-condensing)
Storage Temperature -40 to 85°C
Protection Level IP20
Housing Material PC

Range

Delivering high-precision three-dimensional spatial monitoring at a standard mounting height of 3.0 meters, this 60 GHz eldercare radar sensor provides a horizontal detection range of approximately 5.0 meters x 6.0 meters.

R5-60G-485 detection range, Front View
Front View
R5-60G-485 detection range, Top View
Top View

Dimensions

Recessed mount, product outer diameter 65 mm, product depth 60 mm, cutout diameter 55 mm.

Product Dimensions
Product Dimensions

Applications

R5-60G-485 application: Home
Home
R5-60G-485 application: Eldercare
Eldercare
R5-60G-485 application: Hotel
Hotel
R5-60G-485 application: Lighting
Lighting
R5-60G-485 application: Office
Office
R5-60G-485 application: Security
Security

Mounting

Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to prevent false triggering.

Device Spacing: Maintain a minimum distance of 4 meters between multiple sensors to prevent mutual interference.

Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate surfaces; avoid moving objects directly behind the installation wall/ceiling.

Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.

Disclaimer: Specifications are subject to change without notice. This product is an auxiliary device, not a medical instrument. The manufacturer is not liable for issues caused by improper installation or misuse.

R5-60G-485 wiring diagram
Wiring Diagram
R5-60G-485 wiring diagram
Wiring Diagram

Debugging

IR Remote Control
IR Remote Control

Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.

Control4 - Composer Pro
Control4 - Composer Pro

Control4 Composer Pro is a professional-grade integration software for luxury whole-home audio/video and automation systems, exclusively available to certified dealers to seamlessly integrate entertainment hubs, complex subsystems, and custom smart scenes.

FAQ

What physical system interfacing interfaces does the R5-60G-485 provide?

Provides a standard RS485 bus interface (supporting Modbus-RTU protocol) for detailed point cloud and trajectory data output; and simultaneously provides 1-channel dry contact output for outputting simple alarm levels (supporting NO/NC modes).

What special function do the internal dual dry contact channels have?

Manual correction: This 485 composite version provides 1 channel of dry contact. It is usually used to directly send emergency alarm signals like "fall" or "out of bed" to third-party alarm panels at nursing stations, achieving hardwire-level lightning-fast response.

What is the system power supply specification?

This model is a pure low-voltage version. It requires a centralized DC 12 ~ 30 V regulated power supply on-site. Due to high computing power, the single device power consumption can reach 3 W.

How important is directional alignment when performing fall and bed monitoring?

Extremely important. Because the 60G radar builds spatial posture maps through point clouds, if the direction markings on the sensing surface are not strictly aligned with the room's reference lines (e.g., the edge of the bed) during installation, it will cause the posture recognition matrix to be completely wrong.

Why must large metal reflective surfaces nearby be avoided?

Large areas of metal not only shield 60GHz microwave signals but also generate extremely strong "mirror false target" echoes, severely interfering with the radar's judgment of real human fall trajectories.

What are the body dimensions and installation depth requirements?

Outer diameter 65 mm, height 60 mm. Cutout diameter is 55 mm, and the vertical clearance inside the ceiling must be greater than 65 mm.

Is an illuminance meter integrated to combine with automation scenes?

Yes, a built-in 0 ~ 32,000 Lux light sensor allows lighting data to be uploaded to the main console along with Modbus telegrams.

When gibberish appears on the RS485 network, how to troubleshoot via non-bus methods?

You can use the RC1 remote locally aimed at the body to forcibly issue configuration commands to verify whether the sensor's own software and hardware are working normally.

Resources