The CTL-SEN-R1/1201 is a professional Passive Infrared (PIR) Curtain Motion Sensor powered by advanced pyroelectric sensing technology. Featuring a precision spherical lens design, it provides high-density coverage to accurately capture human movement within a focused 20° field of view. With a detection range of up to 6.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux) , it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.
Features
Equipped with PIR motion detection.
Quad-element PIR technology enhances radial movement detection and minimizes blind spots.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Specifications
Communication Type
Dry Contact
Input Voltage
DC 12 to 30 V
Power Consumption
0.5 W (Max)
Dry Contact Output
Normally Open Mode, Normally Closed Mode, Normally Open Pulse, Normally Closed Pulse
Dry Contact Load
≤ 30 V, ≤ 50 mA
Indicator Light
LED
Detection Mode
Pyroelectric Infrared Receiver
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 3.2 m
Detection Angle
20°
Detection Range
When the installation height is 3.0 m, the motion detection diameter is ≤ 6.0 m
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ50 mm x 60 mm
Cutout Size
Φ42 mm
Product Weight
39.5 g
Cable Assembly
UL1007 22AWG Cable Length: 150 mm
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Engineered with directional narrow-beam detection characteristics, this PIR curtain motion sensor features a long-axis detection angle of 90° and a short-axis (thickness) detection angle of 20°. At a standard mounting height of 3.0 meters, it delivers a bottom detection width of approximately 0.9 meters along the short axis and a maximum coverage span of up to 6.0 meters along the long axis.
Front View
Side View
Dimensions
Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Avoidance: Avoid installing near moving objects (e.g., pets, swinging curtains) or areas with rapid temperature changes (e.g., AC vents, heat sources) to ensure accuracy and prevent false alarms.
Mounting & Handling: Ensure the installation surface is firm and stable to avoid vibration. Handle the device with care during unpacking and installation to prevent physical damage to the shell or circuit board.
Wiring Safety: Disconnect power before wiring. Use certified cables and strictly follow the diagram to ensure proper circuit protection.
Packaging Disposal: Dispose of packaging materials safely and immediately according to local regulations.
Disclaimer: Product specifications are subject to change without prior notice. Please strictly follow these guidelines; the manufacturer is not liable for performance issues or interference caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
What is the difference between this R1-REL/20 dry contact model and the 485 curtain model above?
R1-PIR-REL/20 only provides pure dry contact signal output, completely lacking an RS485 interface. The mechanical rotary dials on the back of the body are specifically used to quickly set output logic modes and sensing parameters, not communication addresses.
What dry contact output logic modes does the sensor body provide?
Supports four rich output modes: Normally Open, Normally Closed, Normally Open Pulse, and Normally Closed Pulse, perfectly compatible with third-party security alarm access hosts or hotel guest room RCU controllers.
What fatal errors should on-site cleaning staff pay attention to when wiping the Fresnel lens?
The Fresnel lens is an extremely precise optical component. When cleaning, use a soft dust-free cloth to gently brush off dust. Corrosive solvents, hard object scratching, or forceful pressing leading to deformation are strictly prohibited. Once the lens is scratched, it will distort the infrared light spot, causing sensing to fail completely.
How to perform on-site blind adjustment using the mechanical rotary dials on the back of the sensor?
On a low-voltage construction site without a network or computer, directly use a Phillips screwdriver to rotate the two decimal dials on the back, which can combine to achieve fast adjustment of hardware-level "work mode switching" and "basic sensitivity gears".
What is the advantage of the 20° narrow-beam electronic curtain in access areas?
It strictly converges the beam within 20°, forming a narrow infrared defense zone, accurately identifying the line-crossing action of personnel entering or exiting doors, while completely ignoring personnel activities on both sides of the defense zone (such as normal lobby areas), eliminating false alarms.
Is it feasible to install the body in restrooms or damp environments?
Strongly not recommended. The housing protection rating is only IP20, and it lacks waterproof and moisture-proof capabilities. The working environment requires no water vapor condensation (below 95% RH). It is strongly advised to avoid heavy moisture areas like showers to prevent motherboard corrosion.
Is an illuminance detection (Lux) function integrated?
Yes, a 0 ~ 32,000 Lux high-precision ambient light sensor is integrated inside the sensing surface, which can combine with personnel movement to achieve day/night light threshold judgments.
What are the power supply specifications and rear wiring requirements for the sensor?
Adopts DC 12 ~ 30 V centralized low-voltage power supply. The rear wiring port of the body is a PH 2.0 mm 6-Pin socket, and the attached cable specification is UL1007 20AWG.