The CTL-SEN-R1/1127 is a professional Passive Infrared (PIR) motion sensor powered by advanced pyroelectric sensing technology. Featuring a precision spherical lens design , it provides high-density coverage to accurately capture human movement within a 360° field of view. With a comprehensive detection diameter of up to 6.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux) , it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.
Features
Equipped with PIR motion detection.
Quad-element PIR technology enhances radial movement detection and minimizes blind spots.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Features 1 relay output
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Specifications
Communication Type
TY-WiFi
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Relay Output
Normally Open Mode Normally Closed Mode
Relay Load
AC 100 to 240 V, ≤ 2 A
Indicator Light
LED
Detection Mode
Pyroelectric Infrared Receiver
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 3.2 m
Detection Angle
360°
Detection Range
When the installation height is 3.0 m, the motion detection diameter is ≤ 6.0 m
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ50 mm x 60 mm
Cutout Size
Φ42 mm
Product Weight
57 g
Cable Assembly
UL1015 18AWG
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Designed with a multi-zone Fresnel lens, this PIR 360 motion sensor provides large-area, dead-zone-free movement detection with a maximum detection diameter of up to 6.0 meters at a standard mounting height of 3.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Avoidance: Avoid installing near moving objects (e.g., pets, swinging curtains) or areas with rapid temperature changes (e.g., AC vents, heat sources) to ensure accuracy and prevent false alarms.
Mounting & Handling: Ensure the installation surface is firm and stable to avoid vibration. Handle the device with care during unpacking and installation to prevent physical damage to the shell or circuit board.
Wiring Safety: Disconnect power before wiring. Use certified cables and strictly follow the diagram to ensure proper circuit protection.
Packaging Disposal: Dispose of packaging materials safely and immediately according to local regulations.
Disclaimer: Product specifications are subject to change without prior notice. Please strictly follow these guidelines; the manufacturer is not liable for performance issues or interference caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
What is the greatest structural advantage of this R1 series Tuya WiFi high-voltage model?
Highly integrated design. The R1 high-voltage version directly integrates the AC-DC high-voltage power supply, relay, and Tuya WiFi wireless communication module entirely within the deep-barrel body, absolutely requiring no external separate control boxes.
What are the ceiling cutout and depth requirements for the integrated body installation?
Due to completely built-in high-voltage and wireless modules, the body height reaches 60 mm. It requires a ceiling cutout diameter of 42 mm, and the internal ceiling clearance depth must be greater than 65 mm to be inserted.
What are the maximum control load and applicable voltage of the built-in relay?
Built-in 1-channel switching relay supporting direct access to mains AC 100 ~ 240 V, with a maximum load current of 2A (suitable for approx. 300W of lighting load control).
What is the use of the "pairing button" on the back of the sensor body during implementation?
Long-pressing this physical button resets the built-in Tuya WiFi module, entering pairing mode; short-pressing is used to manually test internal relay on/off, greatly facilitating electricians in on-site wiring troubleshooting.
When the external network router disconnects, can the sensor still automatically control the lights?
Yes. Detection judgment and relay trigger logic are completed in a hardwired closed loop within the local detection chip, completely independent of the WiFi external network. Disconnection only affects APP remote monitoring and cloud smart scenes.
If a person sits completely still at a workstation, will the PIR sensor turn off the lights?
There is such a possibility (the "lights out phenomenon"). PIR relies on detecting transverse movement of temperature differences. If personnel remain still for a long time, it may not generate enough infrared signal to trigger. It is recommended to use 24G or ToF sensors for demanding sitting scenarios.
What happens if there are large heat sources or direct sunlight in the installation environment?
What happens if there are large heat sources or direct sunlight in the installation environment?
Is an illuminance detection (Lux) function integrated for "don't turn on lights when it's bright" logic?
Yes, a 0 ~ 32,000 Lux light sensor is configured inside the sensing surface. Light intensity data can be uploaded to the Tuya cloud or used for local energy-saving judgments of not turning on lights when ambient light is sufficient.