The CTL-SEN-R1/1126 is a professional Passive Infrared (PIR) motion sensor powered by advanced pyroelectric sensing technology. Featuring a precision spherical lens design , it provides high-density coverage to accurately capture human movement within a 360° field of view. With a comprehensive detection diameter of up to 6.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux) , it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.
Features
Equipped with PIR motion detection.
Quad-element PIR technology enhances radial movement detection and minimizes blind spots.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Features 1 relay output
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Specifications
Communication Type
TY-WiFi
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Indicator Light
LED
Detection Mode
Pyroelectric Infrared Receiver
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 3.2 m
Detection Angle
360°
Detection Range
When the installation height is 3.0 m, the motion detection diameter is ≤ 6.0 m
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ50 mm x 60 mm
Cutout Size
Φ42 mm
Product Weight
51 g
Cable Assembly
UL1015 18AWG
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Designed with a multi-zone Fresnel lens, this PIR 360 motion sensor provides large-area, dead-zone-free movement detection with a maximum detection diameter of up to 6.0 meters at a standard mounting height of 3.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Avoidance: Avoid installing near moving objects (e.g., pets, swinging curtains) or areas with rapid temperature changes (e.g., AC vents, heat sources) to ensure accuracy and prevent false alarms.
Mounting & Handling: Ensure the installation surface is firm and stable to avoid vibration. Handle the device with care during unpacking and installation to prevent physical damage to the shell or circuit board.
Wiring Safety: Disconnect power before wiring. Use certified cables and strictly follow the diagram to ensure proper circuit protection.
Packaging Disposal: Dispose of packaging materials safely and immediately according to local regulations.
Disclaimer: Product specifications are subject to change without prior notice. Please strictly follow these guidelines; the manufacturer is not liable for performance issues or interference caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
This R1-TYW model has no relay. What is its main role in the system?
Acting as a highly sensitive pure data collection sensor node for personnel status and illuminance, reporting information via the internally integrated Tuya WiFi module to trigger cloud automation scenes for other smart devices like luminaires and ACs on the same network.
For the pure data version without a relay, is a separate low-voltage power supply required?
No. The rear of the body directly provides mains input ports, supporting direct access to AC 100~240 V (the body internally contains an AC-DC conversion circuit directly powering the low-voltage motherboard, eliminating external power boxes).
What is the function of the "pairing button" on the back of the body?
Long press this button to reset the WiFi module inside the body, putting it into the pending pairing mode of the Tuya Smart APP, facilitating quick connection to the building's wireless LAN on-site.
How is the coverage breadth of the quad PIR infrared?
Features a dead-zone-free 360° receiving angle. At a 3-meter height, it covers a 6.0-meter detection diameter, effectively reducing the blind spots of traditional dual-element infrared.
If installed in an office densely packed with glass partitions, is the detection effect affected?
Infrared cannot penetrate glass. Therefore, the sensing surface must absolutely not be blocked by glass or acrylic, and simultaneously, it cannot detect personnel movement on the other side of a glass partition.
What are the dimensions for the ceiling cutout and hiding depth of the cylindrical body?
Body outer diameter 50mm, cutout diameter requires 42mm, overall body length 60mm; the ceiling cavity needs more than 65mm of clearance to push in the body and release the spring clips.
Can sensing parameters be adjusted if there is no network connection on-site?
Supported. Delay times and light threshold commands can be issued directly via the standard RC1 infrared remote controller aimed at the sensing surface, taking effect instantly upon reception.
What are the housing flame retardancy standards and operating environment requirements?
The housing uses high-quality UL94 V-0 flame-retardant PC plastic. Requires indoor operation at -20 to 45°C, humidity below 95%RH in a condensation-free environment.