The CTL-SEN-R1/1101 is a professional Passive Infrared (PIR) motion sensor powered by advanced pyroelectric sensing technology. Featuring a precision spherical lens design , it provides high-density coverage to accurately capture human movement within a 360° field of view. With a comprehensive detection diameter of up to 6.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux) , it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.
Features
Equipped with PIR motion detection.
Quad-element PIR technology enhances radial movement detection and minimizes blind spots.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Specifications
Communication Type
Dry Contact
Input Voltage
DC 12 to 30 V
Power Consumption
0.5 W (Max)
Dry Contact Output
Normally Open Mode, Normally Closed Mode, Normally Open Pulse, Normally Closed Pulse
Dry Contact Load
≤ 30 V, ≤ 50 mA
Indicator Light
LED
Detection Mode
Pyroelectric Infrared Receiver
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 3.2 m
Detection Angle
360°
Detection Range
When the installation height is 3.0 m, the motion detection diameter is ≤ 6.0 m
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ50 mm x 60 mm
Cutout Size
Φ42 mm
Product Weight
37.5 g
Cable Assembly
UL1007 22AWG Cable Length: 150 mm
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Designed with a multi-zone Fresnel lens, this PIR 360 motion sensor provides large-area, dead-zone-free movement detection with a maximum detection diameter of up to 6.0 meters at a standard mounting height of 3.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Avoidance: Avoid installing near moving objects (e.g., pets, swinging curtains) or areas with rapid temperature changes (e.g., AC vents, heat sources) to ensure accuracy and prevent false alarms.
Mounting & Handling: Ensure the installation surface is firm and stable to avoid vibration. Handle the device with care during unpacking and installation to prevent physical damage to the shell or circuit board.
Wiring Safety: Disconnect power before wiring. Use certified cables and strictly follow the diagram to ensure proper circuit protection.
Packaging Disposal: Dispose of packaging materials safely and immediately according to local regulations.
Disclaimer: Product specifications are subject to change without prior notice. Please strictly follow these guidelines; the manufacturer is not liable for performance issues or interference caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
What is the difference between this R1-REL dry contact model and the 485 model above?
R1-REL only provides pure dry contact signal output (without an RS485 interface). The mechanical rotary dials on the back are specifically used to quickly set output logic modes and sensing parameters, rather than setting communication addresses.
What dry contact output logic modes does the sensor body provide?
Supports four output modes: Normally Open, Normally Closed, Normally Open Pulse, and Normally Closed Pulse. Extremely flexible, adaptable to any third-party security alarm host or guest room RCU controller.
What should on-site cleaning staff pay attention to when wiping the Fresnel lens?
The Fresnel lens is an extremely precise optical component. When cleaning, use a soft dust-free cloth to gently wipe it. Corrosive solvents or hard pressing are strictly prohibited. Lens deformation or severe scratching will cause sensing to fail completely.
How to perform on-site blind adjustment using the mechanical rotary dials on the back of the sensor?
Use a Phillips screwdriver to rotate the two decimal dials to combine and achieve fast adjustment of hardware-level "work mode switching" and "basic sensitivity gears", greatly facilitating on-site low-voltage construction without a computer.
What are the power supply specifications and rear wiring gauge for the sensor?
Adopts DC 12 ~ 30 V low-voltage power supply. The rear wiring port is a PH 2.0 mm 6-Pin connector, and the matching factory cable specification is UL1007 20AWG.
Is it feasible to install the body in a restroom shower area?
Strongly not recommended. The housing protection rating is IP20, and it lacks any waterproof and moisture-proof capabilities. The operating environment humidity must be < 95% RH (non-condensing). It is strongly advised to avoid heavy moisture bathing areas to prevent motherboard corrosion.
Is an illuminance detection (Lux) function integrated?
Yes, a 0 ~ 32,000 Lux high-precision light sensor is integrated inside the sensing surface, which can combine with personnel movement to achieve ambient light threshold judgments.
Can parameters be fine-tuned via non-dial methods?
Supported. Besides the mechanical dials, it fully supports more detailed parameter overrides for delay time and sensitivity via the RC1 infrared remote controller aimed at the sensing surface.