The CTL-SEN-Mini/9511.F21 Series is a compact, high-precision motion sensor powered by advanced 5.8G High-Bay radar technology. Designed for discreet architectural integration, it features a miniature form factor (Φ35 mm cutout) while delivering robust detection coverage capable of accurately distinguishing between major and minor motion. This series supports convenient parameter configuration via an IR remote control and offers a wide range of mounting accessories to ensure seamless installation across diverse application scenarios.
Features
Accurately identifies major motion and minor motion.
Sensitivity and detection range can be adjusted independently.
Features 1 relay output
Supports parameter configuration and status readout via IR remote control.
Indicator LED indicator defaults to OFF; configurable to Breathing or Night Light modes.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Output Type
Mains Output
BOX Input Voltage
AC 100 to 240 V
BOX Output Voltage
DC 12 V (< 500 mA)
Sensor Input Voltage
DC 12 V
Power Consumption
0.5 W (Max)
Relay Output
Normally Open Mode Normally Closed Mode
Relay Load
AC 100 to 240 V, ≤ 5 A
Indicator Light
LED
Detection Mode
5.8G High-Bay Radar
Operating Frequency
5.725 to 5.875 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Achieves a micro-motion detection diameter of at least 10.0 m at 3.0 m height
Detection Range
1.5 to 18.0 m (sensor to target)
Sensitivity
0 to 100%
Delay Time
1 to 3,600 seconds
Product Size
Φ43 mm x 25 mm
Cutout Size
Φ35 mm
Product Weight
16.5 g
BOX Size
121 mm x 35 mm x 26 mm
BOX Weight
88 g
Cable Assembly
UL2468 22AWG Cable Length: 200 mm
Operating Temperature
Indoor -20 to 45°C
Operating Humidity
< 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Front View
Top View
Dimensions
Measuring 43 mm wide and 25 mm deep, this recessed unit fits a 35 mm cutout and requires a minimum ceiling depth of 13 cm.
Product Dimensions
Applications
Hotel
Mounting
Interference Avoidance: Keep away from moving objects (e.g., curtains, plants) and large metal/reflective surfaces.
Device Spacing: Maintain at least 4m between sensors.
Mounting: Install on a stable, vibration-free surface. Ensure no moving objects are behind the wall (signals penetrate non-metals).
Wiring Safety: Turn off power before wiring. Use certified cables and proper circuit protection.
Disclaimer: Follow wiring diagrams strictly. Manufacturer is not liable for improper installation. Specifications subject to change.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
What is the core difference between the S1-Plus version and the S2 version?
The S1-Plus is also purely local hardwired control, equipped with the same sized strip-shaped control box (F21). However, it integrates only 1 high-power relay internally, with a single-channel maximum control current up to 5A, suitable for series-controlling a single high-load main lighting equipment with a total power around 1KW.
How large is the coverage range of the 5.8G radar?
When installed vertically at a 3.0-meter height, it can provide a 360° detection angle, and the micro-motion detection diameter can reach 10.0 meters, offering relatively broad coverage.
What is the safety red line for high-voltage interface construction?
Thoroughly disconnect the main AC power before wiring, and strictly prohibit touching bare terminals on the high-voltage side of the control box while powered on. Since the S1-Plus carries a load power up to 1KW, copper core cables with wire gauges meeting safety regulations must be used to connect to the control box, and the front end needs a standard circuit breaker to provide overload protection.
How to wire if there is a need for forced continuous lighting on-site?
The F21 control box also reserves external manual override switch terminals. After connecting a normal wall switch, operating the switch can bypass the radar detection logic, forcibly keeping the internal relay closed to achieve constant lighting.
What are the installation requirements for ceiling depth?
The probe requires a 35 mm cutout; because the F21 control box has a long volume (121mm), in order to stuff it into the ceiling and complete the bending arrangement of high-voltage cables, it is recommended to leave an avoidance depth space of about 13 cm in the ceiling.
Can the LED indicator inside the body be turned off?
Considering there shouldn't be light pollution in guest rooms at night, the LED indicator is turned off by default at the factory. If there are specific needs, it can be configured as a breathing light or dim night light mode via the remote controller.
Does this device contain a Tuya module?
No. As a pure local control device, it relies entirely on physical hardwired circuits for status judgment and action execution, involving no network communication connections.
What should be noted when there are metal/glass structures in the installation environment?
5.8G microwaves will generate strong reflections and cluttered echoes against large areas of metal. The front of the sensing surface should try to avoid being blocked by metal pipelines or mirrors. Glass structures are less likely to block 5.8G signals, but care is needed to prevent it from penetrating glass and sensing outdoor personnel, causing false light turn-ons.