The CTL-SEN-Mini/9211.F22 is a compact, high-precision presence sensor powered by advanced 24GHz FMCW mmWave technology. Designed for discreet, premium applications, it features a miniature form factor (Φ35 mm cutout) and offers a detection diameter of up to 8.0 m.
Features
Accurately identifies motion, micro-motion, and Presence.
Sensitivity and detection distance can be adjusted independently.
Features 2 relay output
Supports parameter configuration and status readout via IR remote control.
Indicator LED indicator defaults to OFF; configurable to Breathing or Night Light modes.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Output Type
Mains Output
BOX Input Voltage
AC 100 to 240 V
BOX Output Voltage
DC 12 V (< 500 mA)
Sensor Input Voltage
DC 12 V
Power Consumption
0.5 W (Max)
Relay Output
Normally Open Mode Normally Closed Mode
Relay Load
AC 100 to 240 V, ≤ 5 A
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Installation at 3.0 m Height: ① Motion & Micro-motion: Detection diameter at least 8.0 m ② Stationary Presence: Detection diameter at least 6.0 m
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0 to 100%
Delay Time
1 to 3,600 seconds
Product Size
Φ43 mm x 25 mm
Cutout Size
Φ35 mm
Product Weight
17.5 g
BOX Size
121 mm x 35 mm x 26 mm
BOX Weight
88 g
Cable Assembly
UL2468 22AWG Cable Length: 200 mm
Operating Temperature
Indoor -20 to 45°C
Operating Humidity
< 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Front View
Side View
Dimensions
Measuring 43 mm wide and 25 mm deep, this recessed unit fits a 35 mm cutout and requires a minimum ceiling depth of 13 cm.
Product Dimensions
Applications
Hotel
Mounting
Interference Avoidance: Keep away from moving objects (e.g., curtains, plants) and large metal/reflective surfaces.
Device Spacing: Maintain at least 4m between sensors.
Mounting: Install on a stable, vibration-free surface. Ensure no moving objects are behind the wall (signals penetrate non-metals).
Wiring Safety: Turn off power before wiring. Use certified cables and proper circuit protection.
Disclaimer: Follow wiring diagrams strictly. Manufacturer is not liable for improper installation. Specifications subject to change.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
As a guest control radar, why is it equipped with 2 high-voltage relays (S2)?
Guest room entryways or restrooms usually have two sets of lighting needs (e.g., main light and exhaust fan/mirror light). The matching SWITCH x2 BOX has built-in dual relays with a total control power of up to 1kW (5A per channel), capable of simultaneously linking two sets of independent high-voltage equipment through the same probe, lowering the hotel's hardware costs.
What is the advantage of 24GHz FMCW radar during sitting or sleeping in the guest room?
Traditional infrared (PIR) is hard-pressed to detect a stationary human body. This probe uses 24GHz FMCW technology, which can penetrate bedding to accurately capture the guest's weak chest breathing undulations, significantly improving the terrible experience of sudden power/light cut-offs when guests are in deep sleep or sitting still reading.
Does this model support mobile APP or Tuya network control?
No. This is a pure local hardwired control model. Neither the probe nor the control box contains any wireless communication modules. It relies on low-level radar algorithms to directly and hard-control the internal relays, featuring fast response and no risk of network disconnection.
If there is a need for forced constant lighting for cleaning on-site, how should it be wired?
The control box has a "manual override switch" terminal. Simply connecting a normal wall mechanical switch to this terminal can bypass the radar detection logic, forcibly keeping the relay closed to meet constant lighting needs such as room cleaning.
Will exhaust fans in the installation environment cause severe interference?
Yes. 24G microwaves are sensitive to mechanical vibrations, and the regular rotation of fans is easily judged as continuous personnel activity. The radar sensing surface must be installed away from air vents and vibration sources, and fixed on a stable ceiling.
What are the cutout size and ceiling hiding depth requirements for the body?
The probe cutout requires 35 mm, which is very compact. However, because the matching dual-channel control box (BOX) has a length of 121 mm, to facilitate insertion and cable bending, it is recommended that the vertical clearance depth inside the ceiling be no less than 13 cm.
Can it sense a person behind a frosted glass bathroom door?
24G millimeter-wave radar has strong non-metallic penetrability and can usually penetrate glass, plasterboard, or thin wood to detect a human body behind it. During installation, sensitivity should be appropriately lowered according to the room layout to avoid falsely sensing activities in the corridor or next door.
How to set sensitivity and delay parameters on-site?
Use the RC1 remote controller aimed directly at the body sensing surface on the ceiling for configuration. The delay supports a wide range setting of 1 ~ 3600 seconds, making the configuration process fast and intuitive.