The CTL-SEN-Mini/9211.F20 is a compact, high-precision presence sensor powered by advanced 24GHz FMCW mmWave technology. Designed for discreet, premium applications, it features a miniature form factor (Φ35 mm cutout) and offers a detection diameter of up to 8.0 m.
Features
Accurately identifies motion, micro-motion, and Presence.
Sensitivity and detection distance can be adjusted independently.
Features 1 relay output
Supports parameter configuration and status readout via IR remote control.
Indicator LED indicator defaults to OFF; configurable to Breathing or Night Light modes.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Output Type
Mains Output
BOX Input Voltage
AC 100 to 240 V
BOX Output Voltage
DC 12 V (< 500 mA)
Sensor Input Voltage
DC 12 V
Power Consumption
0.5 W (Max)
Relay Output
Normally Open Mode Normally Closed Mode
Relay Load
AC 100 to 240 V, ≤ 2 A
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Installation at 3.0 m Height: ① Motion & Micro-motion: Detection diameter at least 8.0 m ② Stationary Presence: Detection diameter at least 6.0 m
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0 to 100%
Delay Time
1 to 3,600 seconds
Product Size
Φ43 mm x 25 mm
Cutout Size
Φ35 mm
Product Weight
17.5 g
BOX Size
84 mm x 26 mm x 21 mm
BOX Weight
43 g
Cable Assembly
UL2468 22AWG Cable Length: 200 mm
Operating Temperature
Indoor -20 to 45°C
Operating Humidity
< 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this 24 GHz radar presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.
Front View
Side View
Dimensions
Measuring 43 mm wide and 25 mm deep, this recessed unit fits a 35 mm cutout and requires a minimum ceiling depth of 10 cm.
Product Dimensions
Applications
Hotel
Mounting
Interference Avoidance: Keep away from moving objects (e.g., curtains, plants) and large metal/reflective surfaces.
Device Spacing: Maintain at least 4m between sensors.
Mounting: Install on a stable, vibration-free surface. Ensure no moving objects are behind the wall (signals penetrate non-metals).
Wiring Safety: Turn off power before wiring. Use certified cables and proper circuit protection.
Disclaimer: Follow wiring diagrams strictly. Manufacturer is not liable for improper installation. Specifications subject to change.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
What is the main advantage of the F20 control box compared to F21?
This is a more compact pure hardwired single-channel control box. Its internal relay maximum load is reduced to 2A (approx. 300W lighting), but the box length is drastically shortened to 84mm. This makes its requirement for ceiling depth lower; a clearance of about 10cm is enough for easy insertion.
Is the sensor probe powered by the control box?
Yes, after mains power connects to the F20 control box, the built-in transformer circuit outputs stable DC 12V exclusively for the front-end radar probe.
Does this model support mobile APP or guest room RCU host communication?
No. It is a purely physical local high-voltage linkage model, containing neither Tuya nor other wireless communication modules, nor RS485 wired communication interfaces. It relies purely on the physical relay for direct light control.
How does the radar perform in hotel sitting and working scenarios?
Performs excellently. FMCW technology can extract subtle breathing characteristics while sitting still. As long as a person is within its 6.0-meter diameter static coverage area, even sitting still for a long time, it can accurately maintain the occupied status, avoiding false light-offs.
Will oscillating electric fans in the installation environment cause interference?
It will cause false triggers. Radar is extremely sensitive to regular mechanical movements. The body must be installed away from electric fans and fixed on a stable, vibration-free ceiling.
Will a large area of metal ceiling on-site affect detection?
It will cause clutter. Metal strongly reflects radar microwaves. You must ensure the sensing surface is completely exposed outside the metal ceiling, strictly prohibiting it from being surrounded or blocked by metal.
How to issue illuminance and delay parameters for a pure local model?
How to issue illuminance and delay parameters for a pure local model?
Is it possible to externally connect a manual switch on-site to control the luminaires?
Supported. The control box is equipped with a manual override switch interface. Connecting a switch can bypass the sensor for forced lighting control, convenient for daily cleaning and maintenance.