The CTL-SEN-R5/2526 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring proprietary signal processing algorithms, it detects micro-motion (such as breathing) to detect stationary presence while effectively filtering non-human interference. With a detection range of up to 10 meters and an integrated high-precision illuminance sensor (0 to 32,000 Lux), it is engineered for advanced smart building applications.
Features
Supports motion, micro-motion, and stationary presence detection.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Communication Type
Tuya-WiFi
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Max. Floor Coverage Diameter ≥ 10 m (at 3.0 m height)
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0% to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ65 mm x 60 mm
Cutout Size
Φ55 mm
Product Weight
77 g
Cable Specification
UL1015 18AWG
Operating Environment
Indoor -20 to 45°C, Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring large-scale spatial coverage at a standard mounting height of 3.0 meters, this enhanced 24 GHz radar presence sensor achieves a horizontal detection diameter of up to 10.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 65 mm, product depth 60 mm, cutout diameter 55 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurityApplication
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to prevent false triggering.
Device Spacing: Maintain a minimum distance of 4 meters between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Specifications are subject to change without notice. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
What are the characteristics of this R5 enhanced Tuya WiFi model in terms of hardware architecture and installation?
Highly built-in all-in-one design. It integrates the AC-DC high-voltage power supply and the Tuya WiFi wireless module entirely within the deep-barrel body, requiring no external control box, allowing direct mains connection. However, note that this model has no built-in relay and cannot control lights directly; it primarily serves as a pure data collection node.
How much has the detection range of the enhanced version (R5 25XX series) increased compared to the standard version?
The coverage capability is significantly improved. At a mounting height of 3.0 meters, the maximum detection diameter for static and micro-motion on the ground for the enhanced R5 reaches 10 meters (compared to 6~8 meters for the standard version), making it highly suitable for large conference rooms or open-plan office areas.
How does a pure data node without a relay linkage-control lights on-site?
After the probe detects personnel occupancy, it uses the internal Tuya WiFi to report directly to the cloud. Through the automation scene logic of the Tuya APP, it wirelessly controls other smart switch panels or DALI dimming devices mounted on the LAN to turn on the lights.
What is the function of the "pairing button" on the back of the sensor body?
Long-pressing this hidden physical button resets the built-in WiFi module, putting the device into the Tuya Smart APP's pending pairing mode, facilitating electricians to quickly complete network connection on-site.
When the external network router disconnects, can the Tuya WiFi pure data sensor still control the lights?
No. The pure data version has no physical hardwire connection to luminaires and relies entirely on the router and cloud scenes. Therefore, when the router loses power or the WAN drops, automated light control will temporarily fail.
What are the ceiling cutout and depth requirements for the integrated body installation?
The body outer diameter is 65 mm, and the height reaches 60 mm. It requires a ceiling cutout diameter of 55 mm, and the vertical clearance depth above inside the ceiling must be greater than 65 mm to insert the body.
Will a thin metal ceiling on-site cause severe interference during installation?
Will a thin metal ceiling on-site cause severe interference during installation?
Is an illuminance detection (Lux) function integrated for ambient light judgment?
Yes, a 0 ~ 32,000 Lux high-precision ambient light sensor is configured in the multi-function receiving window on the sensing surface. Light intensity data can be uploaded to the Tuya cloud in real-time, serving as a condition for automation energy-saving judgments like "lights off when illumination is sufficient".