The CTL-SEN-R5/2516 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring proprietary signal processing algorithms, it detects micro-motion (such as breathing) to detect stationary presence while effectively filtering non-human interference. With a detection range of up to 10 meters and an integrated high-precision illuminance sensor (0 to 32,000 Lux), it is engineered for advanced smart building applications.
Features
Supports motion, micro-motion, and stationary presence detection.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Communication Type
Tuya-ZigBee
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Max. Floor Coverage Diameter ≥ 10 m (at 3.0 m height)
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0% to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ65 mm x 60 mm
Cutout Size
Φ55 mm
Product Weight
77 g
Cable Specification
UL1015 18AWG
Operating Environment
Indoor -20 to 45°C, Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring large-scale spatial coverage at a standard mounting height of 3.0 meters, this enhanced 24 GHz radar presence sensor achieves a horizontal detection diameter of up to 10.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 65 mm, product depth 60 mm, cutout diameter 55 mm.
Product Dimensions
Applications
Application
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to prevent false triggering.
Device Spacing: Maintain a minimum distance of 4 meters between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Specifications are subject to change without notice. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
What is the biggest difference between this R5-TYZ model and the integrated high-voltage version?
It is a pure data detection terminal without relays. Power is supplied via a built-in mains-to-low-voltage direct supply (AC 100-240V). It solely relies on the built-in ZigBee module to upload personnel status and lighting data for cloud or local gateway strategy distribution.
What are the on-site wiring requirements for the power supply terminals?
The rear of the body provides standard L and N mains wiring terminals. Simply connecting them to the AC 220V grid will power on the device, which is very convenient.
Why is this pure data sensor suitable for large office areas or classrooms?
Large spaces typically use back-end DALI controllers or large KNX relay cabinets for unified lighting control. Deploying such pure data ZigBee radars as "eyes" on the front-end ceiling saves the redundant cost of relay components inside the detection nodes.
What is the greatest role of 24G radar "static breathing detection"?
In scenarios like conference rooms or restroom toilet stalls, personnel may sit still reading for long periods. Standard infrared falsely turns off lights due to no major movement, whereas 24G radar can 100% maintain light-on judgments through breathing micro-motions.
Will installing in metal gussets or aluminum grilles affect the signal?
It has a fatal impact. Metals completely reflect microwaves, causing radar waves to be "stuffed" inside the ceiling, generating severe clutter echoes and failing. The radar sensing surface must be fully exposed beyond the outer edge of metal plates, or installed avoiding metal structures.
What are the body dimensions and installation depth data?
Sensing surface outer diameter 65 mm, overall height 60 mm, ceiling cutout requires 55 mm, internal space must retain at least 65 mm of deep-barrel push-in space.
Is a 0 ~ 32,000 Lux illuminance meter integrated?
Yes, possesses high-precision ambient light collection capability (±4% error), reportable in real-time via the ZigBee network.
If the site lacks a network, can the sensing distance be adjusted?
Yes. In addition to remote parameter tuning via APP, the site fully supports using the RC1 remote aimed at the sensing surface to issue non-contact sensitivity 0-100% gear modification commands.