The CTL-SEN-R5/2512 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring proprietary signal processing algorithms, it detects micro-motion (such as breathing) to detect stationary presence while effectively filtering non-human interference. With a detection range of up to 10 meters and an integrated high-precision illuminance sensor (0 to 32,000 Lux), it is engineered for advanced smart building applications.
Features
Supports motion, micro-motion, and stationary presence detection.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Features 1 relay output
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Output Type
Mains Output
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Relay Output
Normally Open Mode, Normally Closed Mode
Relay Load
AC 100 to 240 V, ≤ 2 A
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Max. Floor Coverage Diameter ≥ 10 m (at 3.0 m height)
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0% to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ65 mm x 60 mm
Cutout Size
Φ55 mm
Product Weight
87.5 g
Cable Specification
UL1015 18AWG
Operating Environment
Indoor -20 to 45°C, Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring large-scale spatial coverage at a standard mounting height of 3.0 meters, this enhanced 24 GHz radar presence sensor achieves a horizontal detection diameter of up to 10.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 65 mm, product depth 60 mm, cutout diameter 55 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurityApplication
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to prevent false triggering.
Device Spacing: Maintain a minimum distance of 4 meters between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Specifications are subject to change without notice. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
Does this R5 enhanced S1 model support wireless control or Tuya protocols?
No. This is a pure local high-voltage hardwired control version. The body integrates a 1-channel switching relay internally to directly control luminaires, absolutely containing no Tuya WiFi/ZigBee modules.
How large is the detection range of the enhanced version (R5 25XX series) when the angle is not adjusted?
At a 3m mounting height, the radar emits a 360° beam vertically downwards, and the ground detection circle diameter reaches an astonishing 10.0 meters, with a coverage area far exceeding the standard version.
How much luminaire power can the relay of this model control?
The built-in relay supports direct access to AC 100 ~ 240V mains, with a maximum load current of 2A, capable of controlling approx. 300W of general lighting load.
What is the function of the "test button" on the back of the sensor body?
For electricians to quickly verify whether the high-voltage wiring is correct on-site. Pressing the test button forces the internal relay to close and light up the luminaire, and releasing it opens the relay.
What are the body dimensions and ceiling cutout requirements?
The body height reaches 60mm and outer diameter is 65mm. It requires a ceiling cutout of 55 mm, and the vertical ceiling clearance depth must be greater than 65 mm to push in.
Will encountering a thin wooden wall during on-site installation cause false alarms next door?
Yes. 24G millimeter-wave radar has extremely strong non-metallic penetrability. Ensure no personnel walk behind the wall during installation, and you must use the remote control to lower the sensitivity to shrink the detection range.
Is an illuminance sensor (Lux) integrated for local optical environment judgment?
Yes, a 0 ~ 32,000 Lux high-precision ambient light sensor is integrated on the sensing surface, which can combine with personnel movement to achieve the local logic of "lights off during the day when light is sufficient".
How to set sensitivity and delay parameters on-site?
Under pure hardwired control, the site must use the RC1 infrared remote controller aimed directly at the sensor sensing surface for non-contact parameter issuance; light-off delay supports free setting from 1 ~ 3600 seconds.