The CTL-SEN-R5/2508 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring proprietary signal processing algorithms, it detects micro-motion (such as breathing) to detect stationary presence while effectively filtering non-human interference. With a detection range of up to 10 meters and an integrated high-precision illuminance sensor (0 to 32,000 Lux), it is engineered for advanced smart building applications.
Features
Supports motion, micro-motion, and stationary presence detection.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Supports multiple protocols via RS485, including Modbus-RTU and Active Reporting.
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Communication Type
RS485 + Dry Contact
Input Voltage
DC 12 to 30 V
Power Consumption
0.5 W (Max)
Serial Port Settings
Baud Rate: 1200 to 115200 Data Bits: 8 Parity: None, Even, Odd Stop Bits: 1 to 2 Default: 9600, 8, None, 1
Address Range
01 to 99 (Decimal)
Dry Contact Output
Normally Open Mode, Normally Closed Mode, Normally Open Pulse, Normally Closed Pulse
Dry Contact Load
AC or DC ≤ 30 V, ≤ 200mA
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Max. Floor Coverage Diameter ≥ 10 m (at 3.0 m height)
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0% to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ65 mm x 60 mm
Cutout Size
Φ55 mm
Product Weight
61.5 g
Cable Assembly
UL1007 20AWG Cable Length: 150 mm
Operating Environment
Indoor -20 to 45°C, Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring large-scale spatial coverage at a standard mounting height of 3.0 meters, this enhanced 24 GHz radar presence sensor achieves a horizontal detection diameter of up to 10.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 65 mm, product depth 60 mm, cutout diameter 55 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurityApplication
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to prevent false triggering.
Device Spacing: Maintain a minimum distance of 4 meters between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Specifications are subject to change without notice. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Control4 - Composer Pro
Control4 Composer Pro is a professional-grade integration software for luxury whole-home audio/video and automation systems, exclusively available to certified dealers to seamlessly integrate entertainment hubs, complex subsystems, and custom smart scenes.
FAQ
What physical low-voltage interfaces does this R5-485 model support?
The rear of the body provides a standard PH2.0 mm 6-Pin cable supporting an RS485 bus interface (Modbus-RTU protocol), and simultaneously provides 1-channel dry contact signal output (supporting Normally Open, Normally Closed, and Pulse modes).
What is the "decimal rotary dial" on the back of the body used to configure?
Specially designed for the 485 bus. Electricians can directly set the RS485 device's slave address (supporting 01 ~ 99 decimal) on-site using a screwdriver on the dial, eliminating the tedious step of writing addresses with a computer.
What is the significance of the "enhanced 10-meter detection" feature in actual large warehouse projects?
At a 3-meter ceiling height, the blind-spot-free monitoring diameter on the bottom surface of a single probe reaches an astonishing 10 meters. It not only captures tiny movements but also detects static occupancy. This means in the same area, the number of detectors needed to be deployed is drastically reduced, lowering comprehensive costs.
What is the power supply specification for the system? Does it require AC power?
This is a pure low-voltage version, absolutely not connecting to AC power. It adopts centrally supplied DC 12 ~ 30 V DC input, with the maximum power consumption per single device not exceeding 0.5 W.
Can the internal dry contact be directly connected in series to control a 220V lighting circuit?
Absolutely not. The dry contact can only withstand a maximum low-voltage signal of 30V/200mA, commonly used for sending short-circuit levels to alarm hosts. To control 220V high-voltage luminaires, a high-power AC contactor must be externally connected at the back end.
How to avoid signal gibberish and ensure anti-interference when wiring multiple RS485 devices over long distances?
A/B signal cables must strictly use twisted shielded pair wires; the bus topology must use standard daisy-chain connection (no star topology); and a 120-ohm terminating resistor must be paralleled at the very last device to absorb reflections. Radar spacing must be >4m to prevent microwave cross-talk.
Will large exhaust fans rotating in the installation environment affect detection?
It will have a severe impact. The mechanical rotation of exhaust fan blades will be accurately captured by the radar's Doppler effect and misjudged as personnel walking continuously. The installation position must be adjusted to avoid the irradiation area where the fan is located.
Before the bus debugging phase, does it support using an infrared remote controller for single-unit local verification?
Yes, supports using the standard RC1 infrared remote controller aimed at the multi-function window of the sensing surface to issue local non-contact sensitivity, delay, and light-sensitive threshold configurations for single-unit verification.