The CTL-SEN-R5/2501 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring proprietary signal processing algorithms, it detects micro-motion (such as breathing) to detect stationary presence while effectively filtering non-human interference. With a detection range of up to 10 meters and an integrated high-precision illuminance sensor (0 to 32,000 Lux), it is engineered for advanced smart building applications.
Features
Supports motion, micro-motion, and stationary presence detection.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Communication Type
Dry Contact
Input Voltage
DC 12 to 30 V
Power Consumption
0.5 W (Max)
Dry Contact Output
Normally Open Mode, Normally Closed Mode, Normally Open Pulse, Normally Closed Pulse
Dry Contact Load
AC or DC ≤ 30 V, ≤ 200 mA
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Max. Floor Coverage Diameter ≥ 10 m (at 3.0 m height)
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0% to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ65 mm x 60 mm
Cutout Size
Φ55 mm
Product Weight
61.5 g
Cable Assembly
UL1007 20AWG Cable Length: 150 mm
Operating Environment
Indoor -20 to 45°C, Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring large-scale spatial coverage at a standard mounting height of 3.0 meters, this enhanced 24 GHz radar presence sensor achieves a horizontal detection diameter of up to 10.0 meters.
Front View
Top View
Dimensions
Recessed mount, product outer diameter 65 mm, product depth 60 mm, cutout diameter 55 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurityApplication
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to prevent false triggering.
Device Spacing: Maintain a minimum distance of 4 meters between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Specifications are subject to change without notice. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
What is the main role of this R5-REL dry contact model in low-voltage systems?
This is a pure low-voltage, non-networked model that only provides pure dry contact signal output. It is used to connect directly to hotel guest room RCU systems, third-party security hosts, or I/O acquisition modules to provide precise human occupancy signals.
What dry contact output logic modes does the sensor body provide?
Supports four output modes: Normally Open, Normally Closed, Normally Open Pulse, and Normally Closed Pulse, flexibly adapting to pin level requirements of different types of third-party control hosts.
Why does this model not have mobile APP setting functions, and how should it be configured?
To ensure pure physical closed-loop and extremely high reliability in engineering projects, wireless modules were removed. In disconnected on-site situations, electricians directly use a Phillips screwdriver to rotate the two decimal dials on the back of the body, which can combine to achieve fast blind adjustment of hardware-level "output modes" and "sensitivities".
Can the internal dry contact directly control 220V downlights in the corridor?
Absolutely not. The dry contact load only supports a maximum low voltage of 30V / 200mA. To control 220V loads, a high-power solid-state relay or AC contactor must be connected in series behind the dry contact.
What are the power supply specifications and rear wiring gauge for the sensor?
Adopts DC 12 ~ 30 V low-voltage power supply. The rear wiring port of the body is a PH 2.0 mm 6-Pin socket, and the matching factory cable is UL1007 20AWG.
Is it feasible to install the body in restrooms or damp environments?
Strongly not recommended. The housing protection rating is only IP20, lacking any waterproof and moisture-proof capabilities. The operating environment humidity must be < 95% RH (non-condensing). It is strongly advised to avoid heavy moisture areas to prevent motherboard short circuits.
How strong is the "dead-zone-free" capability of the 24GHz millimeter-wave radar compared to ordinary infrared?
Extremely strong. It can omnidirectionally capture weak static breathing signals 360°, with a static detection diameter reaching an astonishing 10.0 meters at a 3-meter mounting height. Whether a human body is partially blocked or completely still, it ensures no false judgment of absence.
Can parameters be fine-tuned via non-dial methods?
Supported. Besides coarse adjustments with the mechanical dials, the site still fully supports using the RC1 infrared remote controller aimed at the receiving window on the sensing surface to perform more detailed parameter overrides for delay time and sensitivity.