The CTL-SEN-R5/2326 is a high-precision 24GHz millimeter-wave radar sensor designed for advanced occupancy detection. It features an adjustable range of 1.5 to 7m with centimeter-level accuracy and a flexible 0° to 60° tilt design for versatile installation. Beyond detecting movement, its "micro-motion" technology can identify static presence (like breathing), while customizable sensing zones and an integrated ambient light sensor enable intelligent automation for smart homes, offices, and healthcare, ensuring efficient energy management based on real-time human displacement.
Features
Supports motion, micro-motion, and stationary presence detection.
Features customizable multi-zone sensing (Segments A/B/C) and configurable proximity/recession distance thresholds.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Sensitivity and detection range can be configured independently.
Features a 0 to 60° adjustable detection angle for precise zone targeting.
Supports parameter configuration and query via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Specifications
Communication Type
Tuya-WiFi
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Mounting Height: 3 m At 0°: Φ 1.5 m detection range At 60°: 3.0 x 7.0 m detection range
Detection Range
1.5 to 7.0 m (sensor to target)
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ65 mm x 60 mm
Cutout Size
Φ55 mm
Product Weight
74.5 g
Cable Specification
UL1015 18AWG
Operating Temperature
Indoor -20 to 45°C
Operating Humidity
< 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Supporting flexible installation angle adjustments, this radar ranging sensor provides distinct coverage patterns at a standard mounting height of 3.0 meters:
0° vertical mounting: Delivers a circularly symmetrical coverage with a horizontal detection diameter of approximately 1.5 meters.
60° angled mounting: Delivers a directional fan-shaped/elliptical coverage, achieving a maximum forward detection span of up to 6.8 meters, a backward detection range of approximately 0.2 meters, a maximum overall transverse width of approximately 7.0 meters, and a longitudinal span of approximately 3.0 meters.
0° Front View
0° Front View
0° Top View
0° Top View
60° Front View
60° Front View
Dimensions
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to prevent false triggering.
Device Spacing: Maintain a minimum distance of 4 meters between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Specifications are subject to change without notice. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
This R5-Rang-TYW pure data version has no relay. What is its main role in the system?
Acting as a pure data collection node for personnel status and illuminance with advanced ranging functions. It reports precise distance and presence information via the fully built-in Tuya WiFi module in the body to trigger cloud automation scenes for smart panels, dimmers, and other devices on the same network.
What is the power supply voltage specification of the device? Does it need an external power adapter to be configured?
Absolutely no external power supply is needed. The rear of the body directly provides mains input ports, supporting direct access to AC 100~240 V (the body internally contains an AC-DC conversion circuit directly powering the low-voltage motherboard).
What is the function of the "pairing button" on the back of the body?
Long press this button to reset the internally integrated WiFi module, putting the device into the Tuya Smart APP's pending pairing mode, facilitating quick connection to the wireless LAN on-site.
How is the ranging coverage of the 24G millimeter wave?
Features a 0-60° flexible tilt design. When vertically downwards at a 3-meter height, the detection diameter is only 1.5 meters, but when the sensing surface is deflected to 60°, the ranging can extend to capture micro-motions and breathing of targets up to 7 meters ahead.
What are the rigid spacing requirements between devices during on-site wiring to prevent microwave cross-talk?
Radar microwave emissions are pervasive. To avoid co-frequency microwave mutual interference causing false alarms, a physical straight-line spacing of at least 4 meters must be strictly maintained between two adjacent radar devices.
What are the dimensions requirements for the ceiling cutout and hiding depth of the cylindrical body?
Body outer diameter is 65mm, cutout requires 55mm, body length 60mm; the ceiling cavity needs more than 65mm of clearance depth to smoothly insert the entire body.
Can sensing parameters be adjusted if there is no network connection or it is offline on-site?
Supported. Delay times and light threshold override commands can be issued directly via the standard RC1 infrared remote controller aimed at the multi-function receiving window on the sensing surface, taking effect instantly upon reception.
What are the housing flame retardancy standards and operating environment requirements?
The housing uses UL94 V-0 fire-rated flame-retardant PC. Requires indoor operation at -20 to 45°C, humidity below 95%RH non-condensing.