The CTL-SEN-R1/2226 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring precise signal processing algorithms, it captures micro-motions (such as breathing) to reliably detect stationary presence. With a comprehensive detection diameter of up to 8.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux), it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.
Features
Accurately identifies motion, micro-motion, and Presence.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Communication Type
TY-WiFi
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Installation at 3.0 m Height: ① Motion & Micro-motion: Detection diameter at least 8.0m ② Stationary Presence: Detection diameter at least 6.0m
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0 to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ50 mm x 60 mm
Cutout Size
Φ42 mm
Product Weight
47 g
Cable Assembly
UL1015 18AWG
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this 24 GHz radar presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.
Front View
Side View
Dimensions
Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to minimize false alarms or unintended triggering.
Device Spacing: Maintain a minimum distance of 4 m between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate non-metallic surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Product specifications are subject to change without prior notice for improvement purposes. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
This R1-TYW low-voltage version has no relay. What is its main role?
Acting as a highly sensitive pure data collection sensor node for personnel status and illuminance, reporting information via internal Tuya WiFi to trigger cloud automation scenes for other smart home devices like luminaires and ACs.
What is the power supply voltage specification of the device?
Wait, correction: The nominal input for this model CTL-SEN-R1/2226 is AC 100~240 V (containing a pure AC-DC conversion circuit directly powering the low-voltage motherboard).
What is the function of the "pairing button" on the back of the sensor?
Long press to reset the device WiFi, putting it into the pending pairing mode of the Tuya Smart APP, facilitating quick local network joining on-site.
How is the coverage breadth and sensitivity of the 24G millimeter wave?
Features a 360° emission angle. At a 3-meter height, it covers 8 meters for dynamic walking and 6 meters for static breathing presence.
What are the rigid spacing requirements for on-site wiring?
Because the radar microwave emission range is wide, to avoid co-frequency cross-talk, a straight-line spacing of at least 4 meters must be strictly maintained between two devices.
What are the dimensions for the cylindrical body cutout and hiding depth?
Sensor diameter 50mm, cutout requires 42mm, body length 60mm; the cavity needs sufficient space to insert the spring clips.
Can parameters be adjusted without a network?
Supported. Delay times and light threshold commands can be issued directly via the standard RC1 infrared remote controller, taking effect instantly.
What are the housing flame retardancy standards and operating environment requirements?
The housing uses UL94 V-0 flame-retardant PC. Requires indoor operation at -20 to 45°C, humidity below 95%RH non-condensing.