$0.00 $0.00
Please choose options.Back to top
Close
$0.00 $0.00
Home > All Products > R1 Series > R1_Tuya Series > 60102226-24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
1/1
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)

24G Radar Presence Sensor (Tuya WiFi)

No.R1-24G-TYW
P/N: 60.10.2226
Model: CTL-SEN-R1/2226
This is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology.
$37.70 $18.90
Received successfully
Coupon Code
CONTINUE SHOPPING
    Please select the information you wantX
Quantity:
-
+
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
1/1
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • 24G Radar Presence Sensor (Tuya WiFi)
  • Description
  • Resources

Overview

The CTL-SEN-R1/2226 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring precise signal processing algorithms, it captures micro-motions (such as breathing) to reliably detect stationary presence. With a comprehensive detection diameter of up to 8.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux), it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.

Features

  • Accurately identifies motion, micro-motion, and Presence.
  • Sensitivity and detection distance can be adjusted independently.
  • Integrated high-precision sensor for accurate indoor illuminance monitoring.
  • Adjustable lighting threshold.
  • Supports parameter configuration and status readout via IR remote control.
  • Indicator LED brightness automatically adjusts to ambient light levels.
  • Powered by a proprietary module with advanced signal processing algorithms.

Specifications

Communication Type TY-WiFi
Input Voltage AC 100 to 240 V
Power Consumption 0.5 W (Max)
Indicator Light LED
Detection Mode 24GHz FMCW Radar
Operating Frequency 24.00 to 24.25 GHz
Transmit Power ≤ 10 dBm
Installation Method Recessed Ceiling Mount
Mounting Height 2.0 to 4.0 m
Detection Angle 360°
Detection Coverage Installation at 3.0 m Height:
① Motion & Micro-motion: Detection diameter at least 8.0m
② Stationary Presence: Detection diameter at least 6.0m
Detection Range 1.5 to 8.0 m (sensor to target)
Sensitivity 0 to 100%
Illuminance Monitoring 0 to 32,000 Lux (Accuracy ±4%)
Delay Time 1 to 3,600 seconds
Product Size Φ50 mm x 60 mm
Cutout Size Φ42 mm
Product Weight 47 g
Cable Assembly UL1015 18AWG
Operating Environment Indoor -20 to 45°C
Humidity < 95% RH (Non-condensing)
Storage Temperature -40 to 85°C
Protection Level IP20
Housing Material PC

Range

Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this 24 GHz radar presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.

R1-24G-TYW detection range, Front View
Front View
R1-24G-TYW detection range, Side View
Side View

Dimensions

Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.

Product Dimensions
Product Dimensions

Applications

R1-24G-TYW application: Home
Home
R1-24G-TYW application: Hotel
Hotel
R1-24G-TYW application: Lighting
Lighting
R1-24G-TYW application: Office
Office
R1-24G-TYW application: Security
Security

Mounting

Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to minimize false alarms or unintended triggering.

Device Spacing: Maintain a minimum distance of 4 m between multiple sensors to prevent mutual interference.

Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate non-metallic surfaces; avoid moving objects directly behind the installation wall/ceiling.

Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.

Disclaimer: Product specifications are subject to change without prior notice for improvement purposes. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.

R1-24G-TYW wiring diagram
Wiring Diagram

Debugging

IR Remote Control
IR Remote Control

Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.

Tuya Smart
Tuya Smart
Tuya Smart
Tuya Smart

Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.

FAQ

This R1-TYW low-voltage version has no relay. What is its main role?

Acting as a highly sensitive pure data collection sensor node for personnel status and illuminance, reporting information via internal Tuya WiFi to trigger cloud automation scenes for other smart home devices like luminaires and ACs.

What is the power supply voltage specification of the device?

Wait, correction: The nominal input for this model CTL-SEN-R1/2226 is AC 100~240 V (containing a pure AC-DC conversion circuit directly powering the low-voltage motherboard).

What is the function of the "pairing button" on the back of the sensor?

Long press to reset the device WiFi, putting it into the pending pairing mode of the Tuya Smart APP, facilitating quick local network joining on-site.

How is the coverage breadth and sensitivity of the 24G millimeter wave?

Features a 360° emission angle. At a 3-meter height, it covers 8 meters for dynamic walking and 6 meters for static breathing presence.

What are the rigid spacing requirements for on-site wiring?

Because the radar microwave emission range is wide, to avoid co-frequency cross-talk, a straight-line spacing of at least 4 meters must be strictly maintained between two devices.

What are the dimensions for the cylindrical body cutout and hiding depth?

Sensor diameter 50mm, cutout requires 42mm, body length 60mm; the cavity needs sufficient space to insert the spring clips.

Can parameters be adjusted without a network?

Supported. Delay times and light threshold commands can be issued directly via the standard RC1 infrared remote controller, taking effect instantly.

What are the housing flame retardancy standards and operating environment requirements?

The housing uses UL94 V-0 flame-retardant PC. Requires indoor operation at -20 to 45°C, humidity below 95%RH non-condensing.

Resources

Available Accessories

Remote Controller
Remote Controller P/N: 60.99.00C1

Model: Accessory (RC1)

Related Links

Frequently Bought Together
more
Frequently Bought Together

Download

Message Us