The CTL-SEN-R1/2217 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring precise signal processing algorithms, it captures micro-motions (such as breathing) to reliably detect stationary presence. With a comprehensive detection diameter of up to 8.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux), it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.
Features
Accurately identifies motion, micro-motion, and Presence.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Features 1 relay output.
Adjustable lighting threshold.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Communication Type
TY-ZigBee
Input Voltage
AC 100 to 240 V
Power Consumption
0.5 W (Max)
Relay Output
Normally Open Mode Normally Closed Mode
Relay Load
AC 100 to 240 V, ≤ 2 A
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Installation at 3.0 m Height: ① Motion & Micro-motion: Detection diameter at least 8.0m ② Stationary Presence: Detection diameter at least 6.0m
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0 to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ50 mm x 60 mm
Cutout Size
Φ42 mm
Product Weight
62.5 g
Cable Assembly
UL1015 18AWG
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this 24 GHz radar presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.
Front View
Side View
Dimensions
Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.
Product Dimensions
Applications
HomeHotelLightingOfficeSecurity
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to minimize false alarms or unintended triggering.
Device Spacing: Maintain a minimum distance of 4 m between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate non-metallic surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Product specifications are subject to change without prior notice for improvement purposes. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
Tuya Smart
Tuya is a global IoT cloud platform and one-stop AIoT solution that provides standardized modules and software support, enabling hardware manufacturers to quickly make traditional products smart and connect them to a rich cloud ecosystem and custom apps.
FAQ
What minimalist implementation advantage does this model have in its hardware architecture?
All-in-one highly integrated design. The AC-DC high-voltage power supply, 1-channel relay switch, and Tuya ZigBee wireless module are all stuffed into the 50x60mm cylindrical probe body, requiring no external control boxes, offering extremely clean wiring inside the ceiling.
What are the maximum control load and applicable voltage of the relay?
The device directly accesses AC 100 ~ 240 V mains power, and the internal relay can control a maximum current of 2A (approx. 300W general lighting load).
What is the stability advantage of the ZigBee communication protocol in large-space applications?
ZigBee provides a low-power wireless communication protocol. Deploying dozens of sensors in a large office won't deplete WiFi router IP resources. Even if the external WAN is disconnected, the local gateway still maintains automatic light switching logic.
What is the troubleshooting use of the physical button on the back of the sensor during implementation?
It serves both as a pairing reset button for the ZigBee gateway (long press) and can be short-pressed to forcibly trigger relay closure to light up luminaires, quickly verifying whether electrician wiring and luminaires work properly.
Will high-frequency radar microwave signals penetrate thin walls and cause false alarms in adjacent rooms?
Yes. 24GHz millimeter waves possess non-metallic penetrability and can easily penetrate plasterboard or thin wooden doors. Therefore, after installation, detection sensitivity must be lowered via APP or remote control to avoid sensing people walking in the corridor outside the wall.
What is the ceiling cutout size requirement?
A hole saw with a diameter of 42 mm must be used to cut a circular hole in the ceiling to embed the body.
Is a high-precision light sensor integrated for combination with automation control?
Yes, a 0 ~ 32,000 Lux light sensor is built into the sensing surface, allowing illuminance data to be transmitted back to the ZigBee gateway in real-time to participate in complex light control automation logic.
Can internal sensor parameters like delay be modified locally when disconnected from the network?
Supported. Using the RC1 infrared remote controller directly transmits commands to override the 1-3600 seconds delay and light control configurations inside the local sensor chip.