The CTL-SEN-R1/2201 is a high-precision human presence sensor powered by advanced 24GHz mmWave radar technology. Featuring precise signal processing algorithms, it captures micro-motions (such as breathing) to reliably detect stationary presence. With a comprehensive detection diameter of up to 8.0 meters and an integrated high-sensitivity illuminance sensor (0 to 32,000 Lux), it is engineered to deliver intelligent, energy-efficient control for diverse smart building applications.
Features
Accurately identifies motion, micro-motion, and Presence.
Sensitivity and detection distance can be adjusted independently.
Integrated high-precision sensor for accurate indoor illuminance monitoring.
Supports parameter configuration and status readout via IR remote control.
Indicator LED brightness automatically adjusts to ambient light levels.
Powered by a proprietary module with advanced signal processing algorithms.
Specifications
Communication Type
Dry Contact
Input Voltage
DC 12 to 30 V
Power Consumption
0.5 W (Max)
Dry Contact Output
Normally Open Mode, Normally Closed Mode, Normally Open Pulse, Normally Closed Pulse
Dry Contact Load
≤ 30 V, ≤ 50 mA
Indicator Light
LED
Detection Mode
24GHz FMCW Radar
Operating Frequency
24.00 to 24.25 GHz
Transmit Power
≤ 10 dBm
Installation Method
Recessed Ceiling Mount
Mounting Height
2.0 to 4.0 m
Detection Angle
360°
Detection Coverage
Installation at 3.0 m Height: ① Motion & Micro-motion: Detection diameter at least 8.0 m ② Stationary Presence: Detection diameter at least 6.0 m
Detection Range
1.5 to 8.0 m (sensor to target)
Sensitivity
0 to 100%
Illuminance Monitoring
0 to 32,000 Lux (Accuracy ±4%)
Delay Time
1 to 3,600 seconds
Product Size
Φ50 mm x 60 mm
Cutout Size
Φ42 mm
Product Weight
39 g
Cable Assembly
UL1007 20AWG Cable Length: 150 mm
Operating Environment
Indoor -20 to 45°C Humidity < 95% RH (Non-condensing)
Storage Temperature
-40 to 85°C
Protection Level
IP20
Housing Material
PC
Range
Featuring advanced spatial coverage at a standard mounting height of 3.0 meters, this 24 GHz radar presence sensor offers a micro-motion/stationary detection coverage diameter of approximately 6.0 meters and a major-motion detection coverage diameter of up to 8.0 meters.
Front View
Side View
Dimensions
Recessed mount, product outer diameter 50 mm, product depth 60 mm, cutout diameter 42 mm.
Product Dimensions
Applications
ApplicationApplication
Mounting
Interference Avoidance: Avoid installing near constantly moving objects (e.g., curtains, plants) or large reflective surfaces (e.g., metal ducts, mirrors) to minimize false alarms or unintended triggering.
Device Spacing: Maintain a minimum distance of 4 m between multiple sensors to prevent mutual interference.
Mounting: Ensure the installation surface is vibration-free. Note that radar signals can penetrate non-metallic surfaces; avoid moving objects directly behind the installation wall/ceiling.
Wiring Safety: Disconnect power before wiring. Use certified cables and ensure the circuit includes appropriate short-circuit and overload protection.
Disclaimer: Product specifications are subject to change without prior notice for improvement purposes. Please follow all wiring diagrams strictly. The manufacturer is not liable for issues caused by improper installation.
Wiring Diagram
Debugging
IR Remote Control
Designed for ultimate convenience and efficiency, this product supports quick on-site configuration and parameter reading using an infrared (IR) remote control. Once deployed, debugging and maintenance can be easily accomplished even without relying on a smart home platform.
FAQ
What is the difference between this R1-REL dry contact model and the 485 model?
R1-REL only provides pure dry contact signal output (without an RS485 communication interface). The physical decimal rotary dial on the back is specifically used to quickly set output modes and parameter thresholds.
What dry contact output modes are provided?
Supports four output modes: Normally Open, Normally Closed, Normally Open Pulse, and Normally Closed Pulse, flexibly adapting to different third-party security or control hosts.
Is it feasible to use dry contacts to directly control high-voltage luminaires?
Absolutely not. The dry contact load only supports a maximum of 30V / 200mA. To control 220V high-voltage loads, an external solid-state relay or high-voltage AC contactor must be connected.
How to operate the mechanical rotary dials on the back of the sensor?
Use a Phillips screwdriver to rotate the two decimal dials to combine and achieve fast blind adjustment of hardware-level "work mode switching" and "basic sensitivity gears", greatly facilitating on-site construction without a computer.
Can the 24GHz radar penetrate glass or thin wooden boards for detection?
Yes, 24GHz millimeter-wave signals have strong non-metallic penetrability (can penetrate plasterboard, wood, glass, etc.), so care must be taken to avoid interference from personnel walking behind walls.
What are the power supply specifications and wire gauge for the sensor?
Adopts DC 12 ~ 30 V low-voltage power supply. The wiring port is a PH 2.0 mm 6-Pin, and the matching factory cable is UL1007 20AWG.
Is it feasible to install in restrooms or damp environments?
The housing protection rating is IP20, and it lacks waterproof and moisture-proof capabilities. The operating environment humidity must be < 95% RH (non-condensing). It is strongly advised to avoid heavy moisture areas.
Does it integrate illuminance detection (Lux) and remote control adjustment?
Integrates a 0 ~ 32,000 Lux high-precision light sensor. Besides the mechanical dials, it fully supports more detailed parameter overrides via the RC1 remote controller.